Two-Stage Torque Motor Servovalve – DY Series

Picture for category Two-Stage Torque Motor Servovalve – DY Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s DY series the unique rigid pin feedback design avoids ball glitch problems, which can occur in other types of servovalves. The valves are rated for 210 Bar (3000 PSI) standard, or can be built for 350 Bar (5000 PSI) service and the pressure ratings are the same for both the tool steel construction or the optional stainless steel spool and body.

Markets:
• Defense
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Power Generation

Features/Benefits:
• No ball glitch
• Lapped spool & body
• Survives high tank port pressures
• Tool steel, or stainless steel, spool & body
• Versatile 21.59 mm (0.850 in.) port circle, can mount to standard 19.81 mm (0.780 in.) and 23.62 mm (0.930 in.) port circle patterns.

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Operating PressureActuation TypeMinimum Operating TemperatureAdditional OptionsBody MaterialWeightSeal MaterialValve TypeDivisionMaximum Operating TemperatureMaximum Flow RateMaximum Operating Pressure (psi)WiringResistance (Ohms)Flow Rate (gpm)Seal Material
DY10AFCNA10
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+180103000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)10Nitrile
DY10AFCNA7.5
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+1807.53000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Nitrile
DY10AFCNB10
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+180105000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)10Nitrile
DY10AFCNB7.5
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+1807.55000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Nitrile
DY10AFCVA10
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+180103000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)10Fluorocarbon
DY10AFCVA7.5
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+1807.53000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Fluorocarbon
DY10AFCVB10
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+180105000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)10Fluorocarbon
DY10AFCVB7.5
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+1807.55000Port C1; (+) signal A, C80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Fluorocarbon
DY10AFDNA10
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+180103000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)10Nitrile
DY10AFDNA7.5
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+1807.53000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Nitrile
DY10AFDNB10
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+180105000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)10Nitrile
DY10AFDNB7.5
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+1807.55000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Nitrile
DY10AFDVA10
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+180103000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)10Fluorocarbon
DY10AFDVA7.5
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+1807.53000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Fluorocarbon
DY10AFDVB10
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+180105000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)10Fluorocarbon
DY10AFDVB7.5
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1FluorocarbonServovalveHydraulic Valve Systems Division+1807.55000Port C1; (+) signal B, D80 Ohms; 80 mA (Parallel); 40 mA (Series)7.5Fluorocarbon
DY10AGCNA10
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+180103000Port C1; (+) signal A, C22 Ohms; 200 mA (Parallel); 100 mA (Series)10Nitrile
DY10AGCNA7.5
Quote Required
TBD
3000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+1807.53000Port C1; (+) signal A, C22 Ohms; 200 mA (Parallel); 100 mA (Series)7.5Nitrile
DY10AGCNB10
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+180105000Port C1; (+) signal A, C22 Ohms; 200 mA (Parallel); 100 mA (Series)10Nitrile
DY10AGCNB7.5
Quote Required
TBD
5000.0Hydraulic Pressure+30Consult catalog for additional featuresSteel2.1NitrileServovalveHydraulic Valve Systems Division+1807.55000Port C1; (+) signal A, C22 Ohms; 200 mA (Parallel); 100 mA (Series)7.5Nitrile