Two-Stage Torque Motor Servovalve – DY Series

Picture for category Two-Stage Torque Motor Servovalve – DY Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s DY series the unique rigid pin feedback design avoids ball glitch problems, which can occur in other types of servovalves. The valves are rated for 210 Bar (3000 PSI) standard, or can be built for 350 Bar (5000 PSI) service and the pressure ratings are the same for both the tool steel construction or the optional stainless steel spool and body.

Markets:
• Defense
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Power Generation

Features/Benefits:
• No ball glitch
• Lapped spool & body
• Survives high tank port pressures
• Tool steel, or stainless steel, spool & body
• Versatile 21.59 mm (0.850 in.) port circle, can mount to standard 19.81 mm (0.780 in.) and 23.62 mm (0.930 in.) port circle patterns.

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Operating TemperatureWeightActuation TypeMaximum Operating PressureMinimum Operating TemperatureAdditional OptionsBody MaterialSeal MaterialMaximum Flow RateValve TypeDivisionSeal MaterialMaximum Operating Pressure (psi)Flow Rate (gpm)WiringResistance (Ohms)
DY45AVCNA60
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelNitrile60ServovalveHydraulic Valve Systems DivisionNitrile300060Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCNB40
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelNitrile40ServovalveHydraulic Valve Systems DivisionNitrile500040Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCNB50
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelNitrile50ServovalveHydraulic Valve Systems DivisionNitrile500050Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCNB60
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelNitrile60ServovalveHydraulic Valve Systems DivisionNitrile500060Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCVA40
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelFluorocarbon40ServovalveHydraulic Valve Systems DivisionFluorocarbon300040Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCVA50
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelFluorocarbon50ServovalveHydraulic Valve Systems DivisionFluorocarbon300050Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCVA60
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelFluorocarbon60ServovalveHydraulic Valve Systems DivisionFluorocarbon300060Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCVB40
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelFluorocarbon40ServovalveHydraulic Valve Systems DivisionFluorocarbon500040Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCVB50
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelFluorocarbon50ServovalveHydraulic Valve Systems DivisionFluorocarbon500050Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVCVB60
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelFluorocarbon60ServovalveHydraulic Valve Systems DivisionFluorocarbon500060Port C1; (+) signal A, C1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDNA40
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelNitrile40ServovalveHydraulic Valve Systems DivisionNitrile300040Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDNA50
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelNitrile50ServovalveHydraulic Valve Systems DivisionNitrile300050Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDNA60
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelNitrile60ServovalveHydraulic Valve Systems DivisionNitrile300060Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDNB40
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelNitrile40ServovalveHydraulic Valve Systems DivisionNitrile500040Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDNB50
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelNitrile50ServovalveHydraulic Valve Systems DivisionNitrile500050Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDNB60
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelNitrile60ServovalveHydraulic Valve Systems DivisionNitrile500060Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDVA40
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelFluorocarbon40ServovalveHydraulic Valve Systems DivisionFluorocarbon300040Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDVA50
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelFluorocarbon50ServovalveHydraulic Valve Systems DivisionFluorocarbon300050Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDVA60
Quote Required
TBD
+18016Hydraulic Pressure3000.0+30Consult catalog for additional featuresSteelFluorocarbon60ServovalveHydraulic Valve Systems DivisionFluorocarbon300060Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)
DY45AVDVB40
Quote Required
TBD
+18016Hydraulic Pressure5000.0+30Consult catalog for additional featuresSteelFluorocarbon40ServovalveHydraulic Valve Systems DivisionFluorocarbon500040Port C1; (+) signal B, D1200 Ohms: 40 mA (Parallel); 20 mA (Series)