• Availability & Price
  • Search SKU
Filter by attributes
  • Current (amps)
  • Flow Rate (gpm)
  • Operating Pressure
  • Size
More Filters...
Filter by manufacturer
Manufacturers

Two-Stage Torque Motor Servovalve – BD Series

Picture for category Two-Stage Torque Motor Servovalve – BD Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s BD series valves will provide accurate control of rotary and linear actuators when used in conjunction with Series BD90 and BD101 servo amplifiers or a motion controller.

Markets:
• Defense
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Power Generation

Features/Benefits:
• Rugged reliable trouble-free operation
• Reduced contaminant sensitivity
• Linear flow gain characteristics
• Intrinsically safe model available
• Explosion proof model available

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureFilter Efficiency RatingResponse TimeMaximum Flow RateMinimum Operating TemperatureMaximum Operating PressureResistanceOptionsActuation TypeElectrical ConnectionBody MaterialValve TypeSeal MaterialFlow Rate (gpm)SizeOperating PressureCurrent (amps)
BD15JALNE10
Quote Required
TBD
Hydraulic Valve Systems Division180 °FISO Code 17/15/1210 to 90%, 26 ms ms10 Gal/min30 °F1350 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveNitrile10S041000 - 135060 (Standard)
BD15JALNE15
Quote Required
TBD
Hydraulic Valve Systems Division180 °FISO Code 17/15/1226.0 ms 10 to 90%15 Gal/min30 °F1350 psi60 ΩExplosion ProofHydraulic PressureExplosion ProofAluminumServo ValveNitrile15S041000 - 135060 (Standard)
BD15JALNG2.5
Quote Required
TBD
Hydraulic Valve Systems Division180 °FSAE Class 3 or better26.0 ms 10 to 90%2.5 Gal/min30 °F50 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveNitrile2.5S04200 - 65060 (Standard)
BD15JALNH15
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms15300 psi (5th Port)60CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveNitrile15S040 - 3000 (5th Port)60 (Standard)
BD15JALVB20
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms2030300060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon20S042600 - 300060 (Standard)
BD15JALVC10
Quote Required
TBD
Hydraulic Valve Systems Division180 °FISO Code 17/15/1226.0 ms 10 to 90%10 Gal/min30 °F2500 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon10S042000 - 250060 (Standard)
BD15JALVC2.5
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms2.530250060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon2.5S042000 - 250060 (Standard)
BD15JALVC5
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms530250060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon5S042000 - 250060 (Standard)
BD15JALVD10
Quote Required
TBD
Hydraulic Valve Systems Division180 °FISO Code 17/15/1210 to 90%, 26 ms ms10 Gal/min30 °F1950 psi60 ΩExplosion ProofHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon10S041400 - 195060 (Standard)
BD15JALVD15
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms1530195060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon15S041400 - 195060 (Standard)
BD15JALVD2.5
Quote Required
TBD
Hydraulic Valve Systems Division180 °FSAE Class 3 or better26.0 ms 10 to 90%2.5 Gal/min30 °F1950 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon2.5S041400 - 195060 (Standard)
BD15JALVD5
Quote Required
TBD
Hydraulic Valve Systems Division180 °FSAE Class 3 or better10 to 90%, 26 ms ms5 Gal/min30 °F1950 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon5S041400 - 195060 (Standard)
BD15JALVE1
Quote Required
TBD
Hydraulic Valve Systems Division180 °FISO Code 17/15/1210 to 90%, 26 ms ms1 Gal/min30 °F1350 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon1S041000 - 135060 (Standard)
BD15JALVE10
Quote Required
TBD
Hydraulic Valve Systems Division180 °FSAE Class 3 or better26.0 ms 10 to 90%10 Gal/min30 °F1350 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon10S041000 - 135060 (Standard)
BD15JALVE15
Quote Required
TBD
Hydraulic Valve Systems Division180 °FSAE Class 3 or better10 to 90%, 26 ms ms15 Gal/min30 °F1350 psi60 ΩExplosion ProofHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon15S041000 - 135060 (Standard)
BD15JALVE20
Quote Required
TBD
Hydraulic Valve Systems Division180 °FISO Code 17/15/1210 to 90%, 26 ms ms20 Gal/min30 °F1350 psi60 ΩCSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon20S041000 - 135060 (Standard)
BD15JALVF2.5
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms2.5305060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon2.5S04700 - 95060 (Standard)
BD15JALVF5
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms5305060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon5S04700 - 95060 (Standard)
BD15JALVG1
Quote Required
TBD
Hydraulic Valve Systems Division180ISO Code 17/15/1210 to 90%, 26 ms1305060CSA ApprovedHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon1S04200 - 65060 (Standard)
BD15JALVG10
Quote Required
TBD
Hydraulic Valve Systems Division180 °FSAE Class 3 or better26.0 ms 10 to 90%10 Gal/min30 °F50 psi60 ΩExplosion ProofHydraulic PressureExplosion ProofAluminumServo ValveFluorocarbon10S04200 - 65060 (Standard)