• Availability & Price
  • Search SKU
Filter by attributes
  • Electrical Requirements
  • Maximum Flow Rate (cfm)
  • Pressure Dew Point (F)
More Filters...
Filter by manufacturer
Manufacturers

ThermalStar Smart Cycling Refrigerated Air Dryer - TM Series

Picture for category ThermalStar Smart Cycling Refrigerated Air Dryer - TM Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The importance of compressed air as a provider of energy for modern industrial processes is widely known. What is often overlooked, however, is the need to provide quality treatment for this air. In fact, the air entering the system contains condensate which, when cooled, will turn into liquid water, causing extensive damage not only to the compressed air network, but also to the finished product.

These costly contamination problems can be avoided by installing a TM1250 - TM3000 or TM4000 - TM15000 Cycling Refrigerated Air Dryer package complete with Parker domnick hunter filtration. The combination of our refrigerated dryers and high quality filtration provides air quality to ISO 8573.1 Class 1.4.1.

A refrigerated dryer is typically selected to achieve its design performance at the user's most extreme working conditions (ie. a warm summer day with the air compressor operating at maximum load). This maximum condition, however, is very rarely achieved in everyday conditions.

First, the air compressor load will vary significantly during a working day and will rarely be at full load, thereby significantly reducing the load on the dryer itself. Furthermore, average temperatures are well below the maximum inlet and ambient temperatures for which the system has been sized. Reduced temperatures at colder moments during the day and overall temperature reductions during the midseason and winter add a further reduction to the load on the dryer.

Features:

• Best in class dewpoint performance
• Tri Mode Operation allows dryer to operate in cycling, non-cycling or auto mode.
• Unlimited cycling due to unloaded “soft start”
• Multi-stage separation and filtration
• Level actuated drain
• Diagnostic readouts indicate need for service
• Drain light
• Alarm light
• Displays in English or Metric
• Serial Port with MODBUS
• Digital readout air in temperature
• Digital readout ambient or water in temperature
• High inlet temperature warning
• High ambient or water in temperature warning
• Optional eControl Center

Benefits:

• Lower dewpoint temperature achieved with ThermalStar Smart results in cleaner operation
• Longer lasting components
• Upstream malfunction that results in more severe inlet conditions can be readily handled without
• resulting in downstream problems
• Lower operating costs, with no sacrifice in performance
• Dryer runs only as needed
• Environmentally friendly refrigerant
• Tube and shell heat exchanger with grooved tube sheets provide greatest mechanical strength and lowest pressure drop
• Patented flood level control protects refrigeration circuit

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceInstalled Condensate Drain TypeWidthCompatible PrefilterOptional AccessoriesMinimum Operating PressureMaximum Operating TemperatureRefrigerant TypeDepthHeightCompatible Prefilter ElementBrandMaximum Ambient TemperatureWeightCompatible After Filter ElementDivisionMinimum Operating TemperatureConnection TypeMaximum Flow RateCompatible After FilterMinimum Ambient TemperatureProduct TypeMaximum Operating PressureMaximum Inlet Pressure RatingElectrical RequirementsMaximum Flow Rate (cfm)Pressure Dew Point (F)
DF-TM10000-A4
Quote Required
TBD
Level Actuated161DH-AO450RDFI-1Air Cooled Unit-131R404A8395-domnick hunter11511020-Industrial Gas Filtration and Generation Division4110" Flg16990.11DH-AA450RDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz1000039
DF-TM12500-A4
Quote Required
TBD
Level Actuated160DH-AO500SDFI-1Air Cooled Unit-131R404A94111-domnick hunter11513250-Industrial Gas Filtration and Generation Division4112" Flg21237.63DH-AA500SDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz1250039
DF-TM1250-A4
Quote Required
TBD
Level Actuated74AO055JNFIAir Cooled Unit-131R404A4165-domnick hunter1151850-Industrial Gas Filtration and Generation Division413" Flg2123.76AA055JNFI41Compressed Air – Refrigerated200100460V/3Ph/60Hz125039
DF-TM15000-A4
Quote Required
TBD
Level Actuated150DH-AO500SDFI-1Air Cooled Unit-131R404A100120-domnick hunter11514600-Industrial Gas Filtration and Generation Division4112" Flg25485.16DH-AA500SDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz1500039
DF-TM1600-A4
Quote Required
TBD
Level Actuated78DH-AO250ODFI-1Air Cooled Unit-131R404A4872-domnick hunter1152200-Industrial Gas Filtration and Generation Division414" Flg2718.42DH-AA250ODFI-141Compressed Air – Refrigerated200100460V/3Ph/60Hz160039
DF-TM2050-A4
Quote Required
TBD
Level Actuated102DH-AO250ODFI-1Air Cooled Unit-131R404A5476-domnick hunter1153000-Industrial Gas Filtration and Generation Division416" Flg3482.97DH-AA250ODFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz205039
DF-TM2500-A4
Quote Required
TBD
Level Actuated102DH-AO350PDFI-1Air Cooled Unit-131R404A5476-domnick hunter1153370-Industrial Gas Filtration and Generation Division416" Flg4247.53DH-AA300ODFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz250039
DF-TM3000-A4
Quote Required
TBD
Level Actuated108DH-AO350PDFI-1Air Cooled Unit-131R404A6685-domnick hunter1154015-Industrial Gas Filtration and Generation Division416" Flg5097.03DH-AA350PDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz300039
DF-TM4000-A4
Quote Required
TBD
Level Actuated108DH-AO350PDFI-1Air Cooled Unit-131R404A6895-domnick hunter1155680-Industrial Gas Filtration and Generation Division418" Flg6796.04DH-AA350PDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz400039
DF-TM5000-A4
Quote Required
TBD
Level Actuated108DH-AO400QDFI-1Air Cooled Unit-131R404A6895-domnick hunter1156415-Industrial Gas Filtration and Generation Division418" Flg8495.05DH-AA400QDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz500039
DF-TM6000-A4
Quote Required
TBD
Level Actuated146DH-AO400QDFI-1Air Cooled Unit-131R404A7695-domnick hunter1157725-Industrial Gas Filtration and Generation Division418" Flg10194.06DH-AA400QDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz600039
DF-TM8000-A4
Quote Required
TBD
Level Actuated146DH-AO450RDFI-1Air Cooled Unit-131R404A7695-domnick hunter1159610-Industrial Gas Filtration and Generation Division4110" Flg13592.09DH-AA450RDFI-141Compressed Air – Refrigerated150100460V/3Ph/60Hz800039