• Availability & Price
  • Search SKU
Filter by attributes
  • Bypass Valve (bar)
  • Bypass Valve Pressure Rating
  • Connection Type
  • Filter Element
  • Filter Element Type
  • Flow Capacity (l/min)
  • Flow Rate
  • Indicator Type
  • Micron Rating
  • Options
More Filters...
Filter by manufacturer
Manufacturers

Tanktop Mounted Return Line Filter - TTF Series

Picture for category Tanktop Mounted Return Line Filter - TTF Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the “In-to-Out” filter principle, contaminated oil cannot leak back into the system during element change.

TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.

Features and Benefits

• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures

• Patented LEIF® elements safeguard filtration quality

• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time

• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter

• Quick response bypass with low hysteresis for improved system protection.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyIndustryDivisionDivisionOperating TemperatureFilter Element TypeOperating PressureApplicationProduct TypeProduct StyleProduct SeriesMounting TypeIndicator Pressure SettingBypass Valve Pressure RatingSeal MaterialMicron RatingFilter Element TypeFlow RateConnection TypeBypass Valve Pressure RatingFilter ElementBypass Valve (bar)OptionsIndicator TypeFlow Capacity (l/min)Port Connection Type
TTF820QBS1EG24A
Quote Required
TBD
ParkerFiltrationConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020Q Microglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20Q Microglass0 to 500 l/minG1½1.5 bar20Q Microglass *1,5 *Diffuser type T, no magnetsElectrical 42V, NO/NC, M10x1300 *G1½ *
TTF820QBS3E2G243
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020Q Microglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20Q Microglass0 to 500 l/min2 x G1½1.5 bar20Q Microglass *1,5 *Diffuser type TElectrical 42V, NC, G1/8300 *2xG1½
TTF820QLBG1EG201
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *No diffuserVisual M10x1300 *G1¼ *
TTF820QLBG1EG203
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *Diffuser type TVisual M10x1300 *G1¼ *
TTF820QLBG1EG20A
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *Diffuser type T, no magnetsVisual M10x1300 *G1¼ *
TTF820QLBG1EG241
Quote Required
TBD
ParkerHydraulicsTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *No diffuserVisual M10x1300 *G1½ *
TTF820QLBG1EG243
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *Diffuser type TVisual M10x1300 *G1½ *
TTF820QLBG1EG24A
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *Diffuser type T, no magnetsVisual M10x1300 *G1½ *
TTF820QLBG2E2G243
Quote Required
TBD
ParkerFiltrationConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 100 °C20QL Ecoglass10 barMobile CranesHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.2 bar1.5 barNitrile20 µm20QL Ecoglass0 to 500 l/min2 x G1½1.5 bar20QL Ecoglass *1,5 *Diffuser type TVisual G1/8300 *2xG1½
TTF820QLBP2EG201
Quote Required
TBD
ParkerHydraulicsConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 100 °C20QL Ecoglass10 barMobile CranesHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5 barNitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *No diffuserNo indicator, port plugged L+R300 *G1¼ *
TTF820QLBP2EG203
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *Diffuser type TNo indicator, port plugged L+R300 *G1¼ *
TTF820QLBP2EG20A
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *Diffuser type T, no magnetsNo indicator, port plugged L+R300 *G1¼ *
TTF820QLBP2EG241
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *No diffuserNo indicator, port plugged L+R300 *G1½ *
TTF820QLBP2EG243
Quote Required
TBD
ParkerHydraulicsTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 100 °C20QL Ecoglass10 barWheel LoadersHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5 barNitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *Diffuser type TNo indicator, port plugged L+R300 *G1½ *
TTF820QLBP2EG24A
Quote Required
TBD
ParkerFiltrationMaterials HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *Diffuser type T, no magnetsNo indicator, port plugged L+R300 *G1½ *
TTF820QLBPEG243
Quote Required
TBD
ParkerFiltrationMaterials HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 100 °C20QL Ecoglass10 barWheel LoadersHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop MountedNo Indicator1.5 barNitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 barDiffuser type TNo indicator, port plugged
TTF820QLBS1EG201
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *No diffuserElectrical 42V, NO/NC, M10x1300 *G1¼ *
TTF820QLBS1EG203
Quote Required
TBD
ParkerHydraulicsConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 100 °C20QL Ecoglass10 barRefuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.2 bar1.5 barNitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *Diffuser type TElectrical 42V, NO/NC, M10x1300 *G1¼ *
TTF820QLBS1EG20A
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1¼1.5 bar20QL Ecoglass *1,5 *Diffuser type T, no magnetsElectrical 42V, NO/NC, M10x1300 *G1¼ *
TTF820QLBS1EG241
Quote Required
TBD
ParkerFiltrationTrucks and BusesHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEA-40 to 10020QL Ecoglass10Refuse TrucksHydraulic Oil FiltersTanktop Mounted Return Line FilterTTF SeriesTanktop Mounted1.21.5Nitrile20 µm20QL Ecoglass0 to 500 l/minG1½1.5 bar20QL Ecoglass *1,5 *No diffuserElectrical 42V, NO/NC, M10x1300 *G1½ *