- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve (bar)
- Bypass Valve Pressure Rating
- Connection Type
- Filter Element
- Filter Element Type
- Flow Capacity (l/min)
- Flow Rate
- Indicator Type
- Micron Rating
- Options
Filter by manufacturer
Tanktop Mounted Return Line Filter - TTF Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the “In-to-Out” filter principle, contaminated oil cannot leak back into the system during element change.
TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.
Features and Benefits
• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures
• Patented LEIF® elements safeguard filtration quality
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time
• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter
• Quick response bypass with low hysteresis for improved system protection.
Read More...TTF filters are available in formats capable of handling flow rates up to 500 l/min. They can operate up to a maximum working pressure of 10 bar. Options include a filling port in the filter cover, a second return port and customised diffusers can be specified.
Features and Benefits
• 10 bar rated filter can be utilised for severe return line applications for reduced downtime due to premature filter failures
• Patented LEIF® elements safeguard filtration quality
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved cleanliness levels and extended element life time
• In-to-out filtration means captured contamination is retained inside the element preventing recontamination of the filter
• Quick response bypass with low hysteresis for improved system protection.
| Action | Part No. | Availability | Partner Available | Price | Operating Temperature | Industry | Bypass Valve Pressure Rating | Filter Element Type | Product Style | Product Type | Mounting Type | Division | Application | Indicator Pressure Setting | Technology | Division | Brand | Operating Pressure | Product Series | Port Connection Type | Flow Capacity (l/min) | Indicator Type | Micron Rating | Filter Element | Filter Element Type | Flow Rate | Seal Material | Connection Type | Options | Bypass Valve Pressure Rating | Bypass Valve (bar) | Specifications Met | Housing Material |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TTF620QLBP2HG243 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 2 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | No Indicator | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 170 * | No indicator, port plugged L+R | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1½ | Diffuser type T | 2.0 bar | 2 | ||||
| TTF620QLBPEG203 | Quote Required | TBD | -40 to 100 °C | Construction | 1.5 bar | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Mobile Cranes | No Indicator | Hydraulics | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 psi | TTF Series | No indicator, port plugged | 20 µm | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1¼ | Diffuser type T | 1.5 bar | ||||||||
| TTF620QLBS1EG201 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1¼ * | 170 * | Electrical 42V, NO/NC, M10x1 | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1¼ | No diffuser | 1.5 bar | 1,5 * | ||||
| TTF620QLBS1EG203 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1¼ * | 170 * | Electrical 42V, NO/NC, M10x1 | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1¼ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF620QLBS1EG20A | Quote Required | TBD | -40 to 100 | Construction | 1.5 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1¼ * | 170 * | Electrical 42V, NO/NC, M10x1 | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1¼ | Diffuser type T, no magnets | 1.5 bar | 1,5 * | ||||
| TTF620QLBS1EG241 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Wheel Loaders | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 170 * | Electrical 42V, NO/NC, M10x1 | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1½ | No diffuser | 1.5 bar | 1,5 * | ||||
| TTF620QLBS1EG243 | Quote Required | TBD | -40 to 100 | Materials Handling | 1.5 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 170 * | Electrical 42V, NO/NC, M10x1 | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1½ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF620QLBS1EG24A | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 20QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Drilling Equipment | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 170 * | Electrical 42V, NO/NC, M10x1 | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 0 to 350 l/min | Nitrile | G1½ | Diffuser type T, no magnets | 1.5 bar | 1,5 * | ||||
| TTF702QBP2EG20B | Quote Required | TBD | -40 to 100 °C | Materials Handling | 1.5 bar | 02Q Microglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | No Indicator | Hydraulics | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 psi | TTF Series | G1¼ * | 230 | No indicator, port plugged L+R | 2 µm | 02Q Microglass | 02Q Microglass | 0 to 120 l/min | Nitrile | G1¼ | Diffuser type P, No magnets | 1.5 bar | 1,5 * | ||||
| TTF702QLBP2EG203 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 02QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Power Packs | No Indicator | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1¼ * | 230 | No indicator, port plugged L+R | 2 µm | 02QL Ecoglass | 02QL Ecoglass | 0 to 120 l/min | Nitrile | G1¼ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF702QLBP2EG243 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 02QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | No Indicator | Hydraulics | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 230 | No indicator, port plugged L+R | 2 µm | 02QL Ecoglass | 02QL Ecoglass | 0 to 120 l/min | Nitrile | G1½ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF7040WBG1BG243 | Quote Required | TBD | -40 to 100 °C | Materials Handling | 0.8 bar | 040W Wiremesh | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Mobile Cranes | 0.7 bar | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 10 bar | TTF Series | Visual M10x1 | 40 µm | 040W Wiremesh | 0 to 450 l/min | Nitrile | G1½ | Diffuser type T | 0.8 bar | ||||||||
| TTF7040WVP2HG244 | Quote Required | TBD | -20 to 120 | Trucks and Buses | 2 | 040W Wiremesh | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | No Indicator | Hydraulics | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 230 | No indicator, port plugged L+R | 40 µm | 040W Wiremesh | 040W Wiremesh | 0 to 450 l/min | Fluoroelestomer | G1½ | Diffuser type P | 2.0 bar | 2 | Degree of filtration determined by multipass test according to ISO 16889. | Aluminium | ||
| TTF705QBG1EG243 | Quote Required | TBD | -40 to 100 °C | Materials Handling | 1.5 bar | 05Q Microglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Wheel Loaders | 1.2 bar | Hydraulics | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 10 bar | TTF Series | G1½ * | 230 | Visual M10x1 | 5 µm | 05Q Microglass | 05Q Microglass | 0 to 270 l/min | Nitrile | G1½ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF705QBP2EG20D | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 05Q Microglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | No Indicator | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1¼ * | 230 | No indicator, port plugged L+R | 5 µm | 05Q Microglass | 05Q Microglass | 0 to 270 l/min | Nitrile | G1¼ | Diffuser type P, No Magnet, Filling port | 1.5 bar | 1,5 * | ||||
| TTF705QBP2EG24B | Quote Required | TBD | -40 to 100 °C | Materials Handling | 1.5 bar | 05Q Microglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | No Indicator | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 10 bar | TTF Series | G1½ * | 230 | No indicator, port plugged L+R | 5 µm | 05Q Microglass | 05Q Microglass | 0 to 270 l/min | Nitrile | G1½ | Diffuser type P, No magnets | 1.5 bar | 1,5 * | ||||
| TTF705QBPEG203 | Quote Required | TBD | -40 to 100 °C | Trucks and Buses | 1.5 bar | 05Q Microglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Wheel Loaders | No Indicator | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 10 bar | TTF Series | No indicator, port plugged | 5 µm | 05Q Microglass | 0 to 270 l/min | Nitrile | G1¼ | Diffuser type T | 1.5 bar | ||||||||
| TTF705QBS1EG243 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 05Q Microglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 230 | Electrical 42V, NO/NC, M10x1 | 5 µm | 05Q Microglass | 05Q Microglass | 0 to 270 l/min | Nitrile | G1½ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF705QLBG1EG203 | Quote Required | TBD | -40 to 100 °C | Construction | 1.5 bar | 05QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Wheel Loaders | 1.2 bar | Hydraulics | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 psi | TTF Series | G1¼ * | 230 | Visual M10x1 | 5 µm | 05QL Ecoglass * | 05QL Ecoglass | 0 to 270 l/min | Nitrile | G1¼ | Diffuser type T | 1.5 bar | 1,5 * | ||||
| TTF705QLBG1EG243 | Quote Required | TBD | -40 to 100 | Trucks and Buses | 1.5 | 05QL Ecoglass | Tanktop Mounted Return Line Filter | Hydraulic Oil Filters | Tanktop Mounted | Hydraulic & Industrial Process Filtration Division EMEA | Refuse Trucks | 1.2 | Filtration | Hydraulic & Industrial Process Filtration Division EMEA | Parker | 150 | TTF Series | G1½ * | 230 | Visual M10x1 | 5 µm | 05QL Ecoglass * | 05QL Ecoglass | 0 to 270 l/min | Nitrile | G1½ | Diffuser type T | 1.5 bar | 1,5 * |