Standard Pilot Vented Load Control Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
| Action | Part No. | Availability | Partner Available | Price | Maximum Operating Pressure | Seal Material | Division | Division | Pilot Location | Maximum Kinematic Viscosity | Body Material | Minimum Operating Temperature | Weight | Cavity Size | Adjustment Mechanism | Maximum Inlet Pressure Rating | Function | Pilot Pressure Ratio | Holding Pressure | Maximum Operating Temperature | For Fluid Type | Valve Material | Operating Temperature | Filter Efficiency Rating | Flow Rate | Actuation Type | Installation Torque | Mounting Type | Flow Direction | Leak Rate | Port Size | Pressure Control Range | Pressure Control Sensitivity | Maximum Flow Rate | Seal Material | Adjustment Mechanism | Holding Pressure | Pilot Pressure Ratio | Port Size | Mounting Type | Maximum Flow Rate | Pressure Control Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MHB-030-WBAH-52E | Quote Required | TBD | 3000 psi | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -34 °C | 2.5 lb | n/a | Tamper Resistant | 3000 psi | Counterbalance Valve | 3:1 | 3000 psi | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 30 Gal/min | Pilot Operated, Vented | N/A Nm | Single Inline | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting drops/min | SAE-8 | 1500-3000 psi | N/A bar | 112.5 L/min | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 3:1 | SAE-8 | Single Inline | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WBBE-52E | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 2.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 3:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Single Gasket | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 3:1 | SAE-8 | Single Gasket | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WBBH-52E | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 2.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 3:1 | 3000 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Single Gasket | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting | SAE-8 | 1500-3000 | n/a | 30 | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 3:1 | SAE-8 | Single Gasket | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WBDE-52N | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | Internal | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 4.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 3:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Double Inline | Cylinder port C, Valve port V | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 3:1 | SAE-8 | Double Inline | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WBDH-52N | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | Internal | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 4.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 3:1 | 3000 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Double Inline | Cylinder port C, Valve port V | 5 @ 80% of setting | SAE-8 | 1500-3000 | n/a | 30 | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 3:1 | SAE-8 | Double Inline | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WEAE-52E | Quote Required | TBD | 210 bar | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -34 °C | 1.13 kg | n/a | Tamper Resistant | 210 bar | Counterbalance Valve | 6:1 | 1500 psi | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 112.5 L/min | Pilot Operated, Vented | N/A lb-ft | Single Inline | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting drops/min | SAE-8 | 34.5-103.4 bar | N/A bar | 112.5 L/min | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 6:1 | SAE-8 | Single Inline | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WEAH-52E | Quote Required | TBD | 210 bar | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 °F | 1.13 kg | n/a | Tamper Resistant | 3000 psi | Counterbalance Valve | 6:1 | 3000 psi | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 112.5 L/min | Pilot Operated, Vented | N/A Nm | Single Inline | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting drops/min | SAE-8 | 1500-3000 psi | N/A bar | 112.5 L/min | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 6:1 | SAE-8 | Single Inline | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WEBE-52E | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 2.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 6:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Single Gasket | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 6:1 | SAE-8 | Single Gasket | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WEBH-52E | Quote Required | TBD | 210 bar | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 °F | 2.5 lb | n/a | Tamper Resistant | 3000 psi | Counterbalance Valve | 6:1 | 210 bar | +250 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 30 Gal/min | Pilot Operated, Vented | N/A lb-ft | Single Gasket | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting drops/min | SAE-8 | 105-210 bar | N/A psi | 30 Gal/min | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 6:1 | SAE-8 | Single Gasket | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WEDE-52N | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | Internal | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 4.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 6:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Double Inline | Cylinder port C, Valve port V | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 6:1 | SAE-8 | Double Inline | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WEDH-52N | Quote Required | TBD | 3000 psi | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | Internal | 45-2000 SSU (6 to 420 cSt) | Aluminum | -34 °C | 2.05 kg | n/a | Tamper Resistant | 210 bar | Counterbalance Valve | 6:1 | 210 bar | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 30 Gal/min | Pilot Operated, Vented | N/A lb-ft | Double Inline | Cylinder port C, Valve port V | 5 @ 80% of setting drops/min | SAE-8 | 105-210 bar | N/A bar | 30 Gal/min | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 6:1 | SAE-8 | Double Inline | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WJAE-52E | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 2.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 10:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Single Inline | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 10:1 | SAE-8 | Single Inline | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WJAH-52E | Quote Required | TBD | 3000 psi | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -34 °C | 1.13 kg | n/a | Tamper Resistant | 210 bar | Counterbalance Valve | 10:1 | 3000 psi | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 30 Gal/min | Pilot Operated, Vented | N/A Nm | Single Inline | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting drops/min | SAE-8 | 1500-3000 psi | N/A psi | 112.5 L/min | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 10:1 | SAE-8 | Single Inline | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WJBE-52E | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 2.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 10:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Single Gasket | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 10:1 | SAE-8 | Single Gasket | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WJBH-52E | Quote Required | TBD | 210 bar | Nitrile | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 °F | 2.5 lb | n/a | Tamper Resistant | 210 bar | Counterbalance Valve | 10:1 | 3000 psi | +250 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 112.5 L/min | Pilot Operated, Vented | N/A lb-ft | Single Gasket | Cylinder port C, Valve port V, Pilot port P | 5 @ 80% of setting drops/min | SAE-8 | 105-210 bar | N/A bar | 30 Gal/min | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 10:1 | SAE-8 | Single Gasket | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHB-030-WJDE-52N | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | Internal | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 4.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 10:1 | 1500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Double Inline | Cylinder port C, Valve port V | 5 @ 80% of setting | SAE-8 | 500-1500 | n/a | 30 | Nitrile | Tamper Resistant | 1500 PSI, 105 BAR | 10:1 | SAE-8 | Double Inline | 30 GAL/MIN, 112.5 L/MIN | 500-1500 PSI, 34.5-103.4 BAR | ||
| MHB-030-WJDH-52N | Quote Required | TBD | 3000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | Internal | 45-2000 SSU (6 to 420 cSt) | Aluminum | -30 | 4.5 | n/a | Tamper Resistant | 3000 | Counterbalance Valve | 10:1 | 3000 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 30 | Pilot Operated, Vented | N/A | Double Inline | Cylinder port C, Valve port V | 5 @ 80% of setting | SAE-8 | 1500-3000 | n/a | 30 | Nitrile | Tamper Resistant | 3000 PSI, 210 BAR | 10:1 | SAE-8 | Double Inline | 30 GAL/MIN, 112.5 L/MIN | 105-210 B | ||
| MHC-010-VANC-00B | Quote Required | TBD | 5000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | n/a | -30 | 0.88 | CDD-1010 | Shimmed (non-adjustable) | 5000 | Counterbalance Valve | 1:1 | 500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 10 | Pilot Operated, Vented | 68-75 | Threaded Cartridge Valve | Cylinder port 2, Valve port 3, Pilot port 1 | 5 @ 80% of setting | n/a | n/a | n/a | 10 | Nitrile | Shimmed (non-adjustable) | 500 PSI, 34.5 BAR | 1:1 | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | N/A | ||
| MHC-010-VANC-00F | Quote Required | TBD | 5000 | Fluorocarbon | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | n/a | -15 | 0.88 | CDD-1010 | Shimmed (non-adjustable) | 5000 | Counterbalance Valve | 1:1 | 500 | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 10 | Pilot Operated, Vented | 68-75 | Threaded Cartridge Valve | Cylinder port 2, Valve port 3, Pilot port 1 | 5 @ 80% of setting | n/a | n/a | n/a | 10 | Fluorocarbon | Shimmed (non-adjustable) | 500 PSI, 34.5 BAR | 1:1 | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | N/A | ||
| MHC-010-VAND-00B | Quote Required | TBD | 5000 | Nitrile | Hydraulic Valve Systems Division | Hydraulic Systems Division | External | 45-2000 SSU (6 to 420 cSt) | n/a | -30 | 0.88 | CDD-1010 | Shimmed (non-adjustable) | 5000 | Counterbalance Valve | 1:1 | 1000 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | 10 | Pilot Operated, Vented | 68-75 | Threaded Cartridge Valve | Cylinder port 2, Valve port 3, Pilot port 1 | 5 @ 80% of setting | n/a | n/a | n/a | 10 | Nitrile | Shimmed (non-adjustable) | 1000 PSI, 69 BAR | 1:1 | n/a | Threaded Cartridge Valve | 10 GAL/MIN, 37.5 L/MIN | N/A |