*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly precise mass flow controllers provide you the diagnostic stability and repeatability you need for low flow gas applications. Controlling thermal mass flow rates from 0.6 l/m to 1,670 l/m with high precision and <0.2% repeatability.  Rated for 8 separate gas types which are customer field adjustable. Our thermal mass flow controller is available in both digital and analog styles, fully compatible with RS232 and digital protocols such as Profibus.  If you're not sure what gas you're going to use or your process changes, our MFC allows you to migrate to a new gas within your flow range without purchasing a new mass flow controller.

Markets:
• Laboratory and Process Instrumentation
• Pharma/Bio-Pharma Equipment
• Air Quality Monitoring System
• Furnace and Coatings

Features/Benefits:
• Fast, Repeatable and Reliable Performance
• Premium Accuracy with Proven Thermal Mass Flow Sensor and Laminar Flow Element
• Easy to integrate into your new or existing systems
• Asset calibration management software included
• Cleaned for analytical use
• Fails shut with Normally Closed Valve for safe operation
• CE, REACH and RoHS II

Applications:
• Gas Control for Laboratory and Process Equipment
• Burner Ratio Control for Ceramics and Metals
• Process and Environmental Analyzers
• Emissions Monitors and Calibrators

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceValve TypeConnection TypeMaximum Operating TemperatureBody MaterialConnection SizeDivisionMinimum Operating TemperatureLeak RateRepeatabilityTurndown RatioWetted MaterialFlow Rate AccuracySpecifications MetElectrical ConnectionTemperature CoefficientFlow RateWarm-Up TimeSeal MaterialSettling TimeSurface FinishControl StabilityPower ConsumptionConnection MaterialAttitude SensitivityPower Supply VoltagePressure CoefficientPressure Control RangeCommunication Interface
601AVQEFD33V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel6 mmPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 0 to 20 mA Sourcing
601AVQEFD44V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel12 mmPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 0 to 20 mA Sourcing
601AVQEFD55V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel1/2"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 0 to 20 mA Sourcing
601AVQEFD88V
Quote Required
TBD
Normally OpenFace Seal Male70316L Stainless Steel1/4"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 0 to 20 mA Sourcing
601AVQEFD99V
Quote Required
TBD
Normally OpenOther70316L Stainless SteelOtherPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 0 to 20 mA Sourcing
601AVQEGD00V
Quote Required
TBD
Normally OpenNone70316L Stainless SteelNonePrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQEGD22V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel1/4"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQEGD33V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel6 mmPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQEGD44V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel12 mmPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQEGD55V
Quote Required
TBD
Normally OpenCompression70316L Stainless Steel1/2"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQEGD88V
Quote Required
TBD
Normally OpenFace Seal Male70316L Stainless Steel1/4"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQEGD99V
Quote Required
TBD
Normally OpenOther70316L Stainless SteelOtherPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + DeviceNet 4 to 20 mA Sourcing
601AVQMAD00V
Quote Required
TBD
Normally ClosedNone70 °C316L Stainless SteelNonePrecision Fluidics Division-10 °CTested < 2 x 10-9 mbar l/s He L/sec< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C °C20 - 75 L/min30 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2 ATM928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMAD22V
Quote Required
TBD
Normally ClosedCompression70316L Stainless Steel1/4"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMAD33V
Quote Required
TBD
Normally ClosedCompression70316L Stainless Steel6 mmPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMAD44V
Quote Required
TBD
Normally ClosedCompression70316L Stainless Steel12 mmPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMAD55V
Quote Required
TBD
Normally ClosedCompression70316L Stainless Steel1/2"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMAD88V
Quote Required
TBD
Normally ClosedFace Seal Male70316L Stainless Steel1/4"Precision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMAD99V
Quote Required
TBD
Normally ClosedOther70316L Stainless SteelOtherPrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 5 Vdc
601AVQMBD00V
Quote Required
TBD
Normally ClosedNone70316L Stainless SteelNonePrecision Fluidics Division-10Tested < 2 x 10-9 mbar l/s He< 0.2% Reading1 : 50 (in digital mode up to 1 : 187.5)316L Stainless SteelStandard: ± 0.5% Reading plus ± 0.1% Full Scale (± 1% Full Scale for ranges 3 - 5 ml/min; ± 2% Full Scale for ranges < 3 ml/min)IP409-PIN D-CONNECTORZero: < 0.05% Full Scale / °C; span: < 0.05% Reading / °C20 - 7530 min. for optimum accuracy 2 min. for accuracy ±2% Full ScaleViton (Standard)Standard: 2 - 4 seconds0.8 µm typical< ±0.1% Full Scale (typical for 1 l/min N2)Max. 320 mA; Add 50 mA Profibus, if applicable316L Stainless SteelMax. error at 90° off horizontal 0.2% at 1 ATM, typical N2+15 - 24 Vdc0.1 ATM typical N2; 0.01% / ATM typical H2928 PSIARS232 + Modbus - RTU 0 to 10 Vdc