- Availability & Price
- Search SKU
- Application Pressure Requirement
- Body/Elastomer Materials
- Electrical Connection
- Pneumatic Body Connection
- Pneumatic Connection Stem
- Valve Configuration Type
- Voltage (VDC)
Series 11/25/26 - Miniature Solenoid Valve
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s 11/25/26 miniature pneumatic solenoid valves are a robust and proven product with a reputation for reliable and consistent performance. These miniature solenoid valves are the preferred choice of major OEM's in the medical and analytical market. The Series 11 bodies are featured in brass or stainless steel. The Series 25 and 26 bodies are made from nickel-plated brass. The Series 11/25/26 have many customizable features in multiple pneumatic and electrical interface options. These valves are the ideal solution for medical applications requiring low out-gassing and a critical leak seal.
Markets
• Respiratory
• Patient Therapy
• Patient Monitoring
• Anesthesia
Features/Benefits
• Proven performance tested to 260 million life cycles
• Wide range of available electrical connections to simplify valve integration and control
• Manifold mount or barbed tube pneumatic configurations available for added system design flexibility
• Available Analytical and Oxygen Service Clean to minimize contamination
• RoHS compliant
Typical Applications
• Oxygen Conservers
• Oxygen Concentrators
• Compression Therapy
• Gas Chromatography
• Insufflators
• Medical & Analytical Gas Control
| Action | Part No. | Availability | Partner Available | Price | Maximum Operating Pressure | Seal Material | For Fluid Type | Maximum Operating Temperature | Configuration | Input Voltage | Power Consumption | Actuation Type | Minimum Operating Temperature | Body Material | Division | Operation Type | Control Method | Max Order Quantity | Out of Stock Lead Time | Mounting Type | Orifice Size | Industry Application | Length | Width | Electrical Connection | Height | Thermal Compensation | Standard Lead Time | Leak Rate | Shipping Weight | Cycles per Lifetime | Vacuum to Pressure Range | Weight | Function | Flow Rate | Maximum Flow Rate | Connection Type | Connection Size | Voltage (VDC) | Electrical Connection | Body/Elastomer Materials | Valve Configuration Type | Pneumatic Body Connection | Application Pressure Requirement | Pneumatic Connection Stem |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 991-003000-237 | Quote Required | TBD | 6.9 bar | FKM | Gases | 70 °C | n/a | 24 VDC | 2.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.030 inch | Gas Chromatography | 2.04 inch | 0.63 inch | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | Normally Closed/Distributor | 35 SLPM | 35 SLPM | Barb Stem | 10-32 FNPT inch | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-100 psi / .030" Orifice | 1/16" Barbs | ||
| 991-003000-253 | Quote Required | TBD | Precision Fluidics Division | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-100 psi / .030" Orifice | 1/16" Barbs | |||||||||||||||||||||||||||||||||||
| 991-003000-254 | Quote Required | TBD | Precision Fluidics Division | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Open | 10-32 Female Thread | 0-100 psi / .030" Orifice | 1/16" Barbs | |||||||||||||||||||||||||||||||||||
| 991-003000-255 | Quote Required | TBD | Precision Fluidics Division | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-100 psi / .030" Orifice | None | |||||||||||||||||||||||||||||||||||
| 991-003001-026 | Quote Required | TBD | 3.45 bar | FKM | Gases | 158 °F | n/a | 12 VDC | 2.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 1.27 mm | Oxygen Conservers and Concentrators | 51.7 mm | 0.63 inch | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | Normally Closed/Distributor | 28 SLPM | 28 SLPM | Barb Stem | 10-32 FNPT inch | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-50 psi / .050" orifice | 5/64" Barbs | ||
| 991-003001-032 | Quote Required | TBD | 50 psi | FKM | Gases | 70 °C | n/a | 12 VDC | 2.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 1.27 mm | Oxygen Conservers and Concentrators | 51.7 mm | 0.63 inch | 18" Wire Leads | 0.67 inch | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | 2-Way | 28 SLPM | 28 SLPM | Threaded Port | 10-32 FNPT | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-50 psi / .050" orifice | None | ||
| 991-003001-033 | Quote Required | TBD | 50 psi | FKM | Gases | 70 °C | n/a | 24 VDC | 2.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.050 inch | Insufflators | 51.7 mm | 15.9 mm | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | Normally Closed (NC) | 28 SLPM | 28 SLPM | Threaded Port | 10-32 FNPT | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-50 psi / .050" orifice | None | ||
| 991-003001-044 | Quote Required | TBD | 3.45 bar | FKM | Gases | 70 °C | n/a | 12 VDC | 2.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 1.27 mm | Gas Chromatography | 51.7 mm | 0.63 inch | 4-Pin PCB | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | Normally Closed/Distributor | 28 SLPM | 28 SLPM | Barb Stem | 5/64 inch Barb | 12 | 4 PC Pin Mount | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-50 psi / .050" orifice | 5/64" Barbs | ||
| 991-003002-026 | Quote Required | TBD | 50 psi | FKM | Gases | 158 °F | n/a | 12 VDC | 1.0 W | Solenoid | 0 °C | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.76 mm | Oxygen Conservers and Concentrators | 2.04 inch | 0.63 inch | 18" Wire Leads | 0.67 inch | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | 3-Way | 20 SLPM | 20 SLPM | Barb Stem | 5/64 inch Barb | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-50 psi / .030" Orifice | 5/64" Barbs | ||
| 991-003002-029 | Quote Required | TBD | 3.45 bar | FKM | Gases | 70 °C | n/a | 12 VDC | 1.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.030 inch | Oxygen Conservers and Concentrators | 2.04 inch | 0.63 inch | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | Normally Open (NO) | 20 SLPM | 20 SLPM | Barb Stem | 10-32 FNPT inch | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Open | 10-32 Female Thread | 0-50 psi / .030" Orifice | 5/64" Barbs | ||
| 991-003002-033 | Quote Required | TBD | 3.45 bar | FKM | Gases | 158 °F | n/a | 24 VDC | 1.0 W | Solenoid | 0 °C | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.76 mm | Flow control/shut-off | 51.7 mm | 15.9 mm | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | Normally Closed (NC) | 20 SLPM | 20 SLPM | Threaded Port | 10-32 FNPT | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-50 psi / .030" Orifice | None | ||
| 991-003002-039 | Quote Required | TBD | 50 psi | FKM | Gases | 70 °C | n/a | 24 VDC | 1.0 W | Solenoid | 0 °C | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.030 inch | Compression Therapy | 2.04 inch | 0.63 inch | 4-Pin PCB | 0.67 inch | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | 2-Way | 20 SLPM | 20 SLPM | Threaded Port | 10-32 FNPT | 24 | 4 PC Pin Mount | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-50 psi / .030" Orifice | None | ||
| 991-003002-057 | Quote Required | TBD | 3.45 bar | FKM | Gases | 158 °F | n/a | 24 VDC | 1.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.76 mm | Sieve bed switching | 51.7 mm | 15.9 mm | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | 2-Way | 20 SLPM | 20 SLPM | Barb Stem | 10-32 FNPT inch | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Open | 10-32 Female Thread | 0-50 psi / .030" Orifice | 5/64" Barbs | ||
| 991-003002-088 | Quote Required | TBD | Precision Fluidics Division | 5 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-50 psi / .030" Orifice | 1/8" Barbs | |||||||||||||||||||||||||||||||||||
| 991-003002-089 | Quote Required | TBD | 50 psi | FKM | Gases | 158 °F | n/a | 12 VDC | 1.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.030 inch | Compression Therapy | 51.7 mm | 15.9 mm | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | 3-Way | 20 SLPM | 20 SLPM | Barb Stem | 10-32 FNPT inch | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-50 psi / .030" Orifice | 1/8" Barbs | ||
| 991-003003-026 | Quote Required | TBD | 25 psi | FKM | Gases | 158 °F | n/a | 12 VDC | 1.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 1.27 mm | Compression Therapy | 51.7 mm | 15.9 mm | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | 3-Way | 18 SLPM | 18 SLPM | Threaded Port | 5/64 inch Barb | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Closed/Distributor | 10-32 Female Thread | 0-25 psi / .050" Orifice | 5/64" Barbs | ||
| 991-003003-030 | Quote Required | TBD | 1.72 bar | FKM | Gases | 158 °F | n/a | 24 VDC | 1.0 W | Solenoid | 0 °C | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.050 inch | Compression Therapy | 2.04 inch | 0.63 inch | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | Normally Open (NO) | 18 SLPM | 18 SLPM | Threaded Port | 5/64 inch Barb | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 3-Way Normally Open | 10-32 Female Thread | 0-25 psi / .050" Orifice | 5/64" Barbs | ||
| 991-003003-032 | Quote Required | TBD | 25 psi | FKM | Gases | 158 °F | n/a | 12 VDC | 1.0 W | Solenoid | 0 °C | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 1.27 mm | Sieve bed switching | 51.7 mm | 0.63 inch | 18" Wire Leads | 0.67 inch | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | 2-Way | 18 SLPM | 18 SLPM | Threaded Port | 10-32 FNPT | 12 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-25 psi / .050" Orifice | None | ||
| 991-003003-033 | Quote Required | TBD | 1.72 bar | FKM | Gases | 70 °C | n/a | 24 VDC | 1.0 W | Solenoid | 0 °C | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.050 inch | Anesthesia Delivery | 2.04 inch | 15.9 mm | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 60 g | Normally Closed (NC) | 18 SLPM | 18 SLPM | Threaded Port | 10-32 FNPT | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Closed | 10-32 Female Thread | 0-25 psi / .050" Orifice | None | ||
| 991-003003-057 | Quote Required | TBD | 25 psi | FKM | Gases | 70 °C | n/a | 24 VDC | 1.0 W | Solenoid | 32 °F | Nickel-Plated Brass | Precision Fluidics Division | Electronic | Current or Voltage | 9 | 40 | Mounting Screw | 0.050 inch | Sieve bed switching | 51.7 mm | 0.63 inch | 18" Wire Leads | 17.0 mm | Non-Thermally Compensated | 25 | < 0.016 cm3/min of Air | 0.4 | 202 Million | Vacuum to Pressure Rating | 2.1 oz | 2-Way | 18 SLPM | 18 SLPM | Barb Stem | 10-32 FNPT inch | 24 | 18" Wire Leads | Nickel Plated Brass/ FKM | 2-Way Normally Open | 10-32 Female Thread | 0-25 psi / .050" Orifice | 5/64" Barbs |