- Availability & Price
- Search SKU
Filter by attributes
- Filter Element
- Filter Housing Series
Filter by manufacturer
Replacement Elements - Tanktopper Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Having an integrated air breather and optional dipstick the Parker Filtration Tanktopper Series Tank top Mounted Return Line Filters offers an all-in-one total filtration solution.
Tanktopper replacement elements always come with an air breather element. That way both the oil- and the air filter element can be replaced during the service event, improving system protection. Tanktopper replacement elements are available with a variety of high quality filter media packs and a wide choice in micron ratings.
The LEIF Ecoglass element versions with reusable metal sleeve have a patented design that safeguards the use of genuine parts and guarantees quality of filtration.
Fluid passes through the elements in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates re-injection of contaminant during element change, clean fluid then returns to the reservoir.
Using genuine Parker replacement elements guarantees Parker’s quality of filtration. Using after market filters with unknown media quality may save initial cost, but can increase overall costs by requiring more element change outs and potentially causing system downtime. Protect your investment by always buying genuine Parker replacement elements.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Tanktopper replacement elements always come with an air breather element. That way both the oil- and the air filter element can be replaced during the service event, improving system protection. Tanktopper replacement elements are available with a variety of high quality filter media packs and a wide choice in micron ratings.
The LEIF Ecoglass element versions with reusable metal sleeve have a patented design that safeguards the use of genuine parts and guarantees quality of filtration.
Fluid passes through the elements in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates re-injection of contaminant during element change, clean fluid then returns to the reservoir.
Using genuine Parker replacement elements guarantees Parker’s quality of filtration. Using after market filters with unknown media quality may save initial cost, but can increase overall costs by requiring more element change outs and potentially causing system downtime. Protect your investment by always buying genuine Parker replacement elements.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | UOM | Filter Element Type | Division | Maximum Pressure Differential | Diameter | Length | Seal Material | Filter Element | Filter Housing Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 937886Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 149 mm | Nitrile | 02QL Ecoglass | TPR5 (2-120) | |||
| 937887Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 235.0 mm | Nitrile | 02QL Ecoglass | TPR6 (2-200) | |||
| 937888Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 368 mm | Nitrile | 02QL Ecoglass | TPR7 (2-250) | |||
| 937889Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 149 mm | Nitrile | 05QL Ecoglass | TPR5 (2-120) | |||
| 937890Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 235.0 mm | Nitrile | 05QL Ecoglass | TPR6 (2-200) | |||
| 937891Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 368 mm | Nitrile | 05QL Ecoglass | TPR7 (2-250) | |||
| 937892Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 149 mm | Nitrile | 10QL Ecoglass | TPR5 (2-120) | |||
| 937893Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 235.0 mm | Nitrile | 10QL Ecoglass | TPR6 (2-200) | |||
| 937894Q | Quote Required | 2 Limited Stock | $235.44 | EA | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 368 mm | Nitrile | 10QL Ecoglass | TPR7 (2-250) | |
| 937895Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 149 mm | Nitrile | 20QL Ecoglass | TPR5 (2-120) | |||
| 937896Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 235.0 mm | Nitrile | 20QL Ecoglass | TPR6 (2-200) | |||
| 937897Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 79 mm | 368 mm | Nitrile | 20QL Ecoglass | TPR7 (2-250) | |||
| 937898Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 100 mm | Nitrile | 02QL Ecoglass | TPR1 (1-40) | |||
| 937899Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 200 mm | Nitrile | 02QL Ecoglass | TPR2 (1-80) | |||
| 937900Q | Quote Required | $123.96 | EA | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 | 47 mm | 100 mm | Nitrile | 05QL Ecoglass | TPR1 (1-40) | ||
| 937901Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 200 mm | Nitrile | 05QL Ecoglass | TPR2 (1-80) | |||
| 937902Q | Quote Required | $119.83 | EA | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 100 mm | Nitrile | 10QL Ecoglass | TPR1 (1-40) | ||
| 937903Q | Quote Required | $129.48 | EA | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 200 mm | Nitrile | 10QL Ecoglass | TPR2 (1-80) | ||
| 937904Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 100 mm | Nitrile | 20QL Ecoglass | TPR1 (1-40) | |||
| 937905Q | Quote Required | TBD | Eco element for re-usable LEIF sleeve | Hydraulic & Industrial Process Filtration Division EMEA | 10 bar in LEIF Sleeve (ISO 2941) | 47 mm | 200 mm | Nitrile | 20QL Ecoglass | TPR2 (1-80) |