PTFE AWG Tubing for electrical insulation applicationsis most often used in electrical insulation applications. A PTFE tube has a non-stick surface that eliminates media buildup. In electrical applications, AWG tubing is placed over wire/cable as a protective cover that prevents electrical discharge and heat dissipation. PTFE AWG Tubing is sometimes referred to as “Spaghetti Tubing” or “American Wire Gauge Tubing”. It is supplied in natural and available as a custom run in ten different colors. Tubing is available in Standard Wall, Light Wall, Thin Wall and Heavy Wall designs and is the best chemical resistant tubing Parker offers.

Markets:
• Electrical
• Life Science
• Industrial  

Features/Benefits:
• Exceptional resistance to extreme heat or cold
• Best chemical and corrosion resistance
• Lowest coefficient of friction of all plastics
• Superior dielectric strength
• Non-wetting and non-leaching
• Odorless and tasteless makes it ideal for food and beverage applications
• Excellent flex life
• Laser markable
• Resists ultra-violet rays
• Self-extinguishing plastic  

Applications:
• Electrical insulation
• Circuit boards
• Wire insulation
• Protective covering
• Strain relief
• Introducer
• Stent delivery
• Cable liner
• Spacer  

Certifications/Compliance:
• AMS 3653
• 21 CFR 177.1550 Compliant
• USP Class VI Compliant
• Light Wall (TFL) – ASTM D3295 Class 1
• Thin Wall (TFT) – ASTM D3295 Class 2, AMS 3655, CSA 9032-01 300V
• Standard Wall (TFS)  - CSA 9032-01 600V
• Heavy Wall (TFH) – ASTM D3295, Class 4

Technical Specifications:
• Extruded from virgin PTFE (Polytetrafluoroethylene)
• Chemical Resistance: Fluoropolymers withstand most chemicals and solvents except for Elemental Sodium, Elemental Potassium, and Elemental Lithium. Elemental Sodium will remove the fluorine from the polymer molecule and the other metals have a similar affect.
• All dimensions are nominal
• Continuous lengths and colors available as a custom run - Contact customer service
• Qualified with fittings from Parker Fluid System Connectors Division Fittings (See Brass Composite and Thermoplastic Fittings and Valves Catalog CAT3501E USA)
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Operating TemperatureSizeColorTube Outside DiameterSpecifications MetApplicationCompatible FittingTube Inside DiameterWeightMinimum Operating TemperatureTube MaterialLength per PackageMediaOrder SizeTube Inside DiameterStandard Pack Qty (ft)Product TypeTube Wall Thickness
TFS04-NT
Quote Required
TBD
500 °FAWG 4Natural (colors available upon request)0.248 inchUSP Class VISemiconductorTrueSeal™0.208 inch0.0198 kg/m-100 °FPolytetrafluoroethylene (PTFE)Random Length Coils ftHydraulic Fluids (High Temperature)AWG04 Standard Wall0.208random length coilsAWG0.02
TFS05-NT
Quote Required
TBD
260 °CAWG 5Natural (colors available upon request)5.7 mmCSA 9032-01 600VFluid HandlingCompress-Align®4.7 mm0.012 lb/ft-100 °FPolytetrafluoroethylene (PTFE)Random Length Coils ftWaterAWG05 Standard Wall0.185random length coilsAWG0.02
TFS06-NT
Quote Required
TBD
500 °FAWG 6Natural (colors available upon request)5.2 mmUSP Class VIFluid HandlingCompression0.166 inch0.0109 lb/ft-75 °CPolytetrafluoroethylene (PTFE)Random Length Coils ftWaterAWG06 Standard Wall0.166random length coilsAWG0.02
TFS07-NT
Quote Required
TBD
260 °CAWG 7Natural (colors available upon request)4.8 mmAMS 3653GSemiconductorCompress-Align®0.148 inch0.0098 lb/ft-75 °CPolytetrafluoroethylene (PTFE)Random Length Coils ftChemicalsAWG07 Standard Wall0.148random length coilsAWG0.02
TFS08-NT
Quote Required
TBD
500 °FAWG 8Natural (colors available upon request)0.173 inchCSA 9032-01 600VFluid HandlingCompression3.4 mm0.009 lb/ft-75 °CPolytetrafluoroethylene (PTFE)Random Length Coils ftChemicalsAWG08 Standard Wall0.133random length coilsAWG0.02
TFS09-NT
Quote Required
TBD
500 °FAWG 9Natural (colors available upon request)0.158 inchUSP Class VIFluid HandlingCompression0.118 inch0.0081 lb/ft-100 °FPolytetrafluoroethylene (PTFE)Random Length Coils ftChemicalsAWG09 Standard Wall0.118500 ft. spoolAWG0.02
TFS1.00-NT
Quote Required
TBD
500 °F1 inch Standard WallNatural (colors available upon request)27 mmUSP Class VIElectrical InsulationTrueSeal™1.010 inchn/a-75 °CPolytetrafluoroethylene (PTFE)Random Length CoilsChemicals1 Fractional Standard Wall1.01random length coilsObsolete Fractional0.035
TFS1/2-NT
Quote Required
TBD
260 °C1/2 inch Standard WallNatural (colors available upon request)0.557 inchFDA 21 CFR 177.1550SemiconductorTrueSeal™0.507 inchn/a-100 °FPolytetrafluoroethylene (PTFE)Random Length CoilsChemicals1/2 Fractional Standard Wall0.507random length coilsObsolete Fractional0.025
TFS1/32-NT
Quote Required
TBD
260 °C1/32 inch Standard WallNatural (colors available upon request)0.110 inchUSP Class VIElectrical Insulationn/a0.8 mmn/a-75 °CPolytetrafluoroethylene (PTFE)Random Length CoilsHydraulic Fluids (High Temperature)1/32 Fractional Standard Wall0.031random length coilsObsolete Fractional0.02
TFS1/4-NT
Quote Required
TBD
500 °F1/4 inch Standard WallNatural (colors available upon request)7.4 mmUSP Class VIElectrical InsulationTrueSeal™0.250 inchn/a-75 °CPolytetrafluoroethylene (PTFE)Random Length CoilsChemicals1/4 Fractional Standard Wall0.25random length coilsObsolete Fractional0.02
TFS1/8-NT
Quote Required
TBD
500 °F1/8 inch Standard WallNatural (colors available upon request)4 mmUSP Class VIMedicalTrueSeal™3.2 mmn/a-75 °CPolytetrafluoroethylene (PTFE)Random Length CoilsHydraulic Fluids (High Temperature)1/8 Fractional Standard Wall0.125random length coilsObsolete Fractional0.02
TFS10-NT
Quote Required
TBD
260 °CAWG 10Natural (colors available upon request)3.5 mmFDA 21 CFR 177.1550Electrical InsulationTrueSeal™0.106 inch0.0085 kg/m-100 °FPolytetrafluoroethylene (PTFE)500 ft SpoolWaterAWG10 Standard Wall0.106500 ft. spoolAWG0.016
TFS11-NT
Quote Required
TBD
260 °CAWG 11Natural (colors available upon request)0.127 inchAMS 3653GFluid HandlingTrueSeal™2.4 mm0.0077 kg/m-100 °FPolytetrafluoroethylene (PTFE)500 ft SpoolHydraulic Fluids (High Temperature)AWG11 Standard Wall0.095500 ft. spoolAWG0.016
TFS12-NT
Quote Required
TBD
260 °CAWG 12Natural (colors available upon request)3 mmUSP Class VISemiconductorn/a0.085 inch0.0047 lb/ft-75 °CPolytetrafluoroethylene (PTFE)170 m SpoolWaterAWG12 Standard Wall0.085500 ft. spoolAWG0.016
TFS13-NT
Quote Required
TBD
260 °CAWG 13Natural (colors available upon request)2.7 mmUSP Class VIElectrical Insulationn/a1.9 mm0.0043 lb/ft-100 °FPolytetrafluoroethylene (PTFE)170 m SpoolHydraulic Fluids (High Temperature)AWG13 Standard Wall0.076500 ft. spoolAWG0.016
TFS14-NT
Quote Required
TBD
500 °FAWG 14Natural (colors available upon request)0.098 inchCSA 9032-01 600VMedicaln/a0.066 inch0.0057 kg/m-100 °FPolytetrafluoroethylene (PTFE)500 ft SpoolWaterAWG14 Standard Wall0.066500 ft. spoolAWG0.016
TFS15-NT
Quote Required
TBD
260 °CAWG 15Natural (colors available upon request)2.3 mmFDA 21 CFR 177.1550Fluid Handlingn/a0.059 inch0.0059 lb/ft-100 °FPolytetrafluoroethylene (PTFE)170 m SpoolWaterAWG15 Standard Wall0.059500 ft. spoolAWG0.016
TFS16-NT
Quote Required
TBD
260 °CAWG 16Natural (colors available upon request)2.1 mmFDA 21 CFR 177.1550Semiconductorn/a1.4 mm0.0032 lb/ft-100 °FPolytetrafluoroethylene (PTFE)1000 ft SpoolHydraulic Fluids (High Temperature)AWG16 Standard Wall0.0531,000 ft. spoolAWG0.016
TFS17-NT
Quote Required
TBD
260 °CAWG 17Natural (colors available upon request)2 mmFDA 21 CFR 177.1550Semiconductorn/a0.048 inch0.0045 kg/m-75 °CPolytetrafluoroethylene (PTFE)340 m SpoolHydraulic Fluids (High Temperature)AWG17 Standard Wall0.0481,000 ft. spoolAWG0.016
TFS18-NT
Quote Required
TBD
500 °FAWG 18Natural (colors available upon request)1.9 mmUSP Class VIFluid Handlingn/a0.042 inch0.0402 kg/m-75 °CPolytetrafluoroethylene (PTFE)340 m SpoolHydraulic Fluids (High Temperature)AWG18 Standard Wall0.0421,000 ft. spoolAWG0.016