• Availability & Price
  • Search SKU
Filter by attributes
  • Calibration Type
  • For Fluid Type
  • Options
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Portable Particle Monitor – iCount LaserCM

Picture for category Portable Particle Monitor – iCount LaserCM

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Hydraulic fluid cleanliness plays a critical role in the performance and reliability of industrial equipment. Fluids with high levels of contamination and/or solid particulate matter can damage system components, such as pumps, actuators, or servo valves, leading to shorter maintenance intervals, added downtime, and increased costs.

The Parker iCount LaserCM portable particle monitor is a user-friendly field diagnostic device that provides service personnel with the capability to quickly and easily assess the cleanliness of the hydraulic fluid or oil in a wide range of applications. The particle monitor can be utilized while machinery is in operation and is equipped with a number of intuitive features to accommodate users unique requirements, including ISO/NAS/AS standard cleanliness reporting, data entry and graphing, built-in memory storage, and an integral printer.
The iCountLaserCM features microprocessor-controlled optical scanning for accurate contaminant measurement with a calibration range from ISO 7 to ISO 22 with no monitor saturation. The particles are measured by a photo diode that converts light intensity to a voltage output ,which is recorded against time. As the particle moves across the window, the amount of light lost is proportional to the size of the particle. This reduction in voltage is measured and stored in the iCount LaserCM computer in one of six channels according to particle size. Readouts are displayed on the hand-held LCD in the accepted ISO/AS and NAS standards ready for hard copy printing or RS232 computer download. The on-board computer allows storage of up to 300 test results.
The iCount LaserCM’s compact, user-friendly design and ease of use set it apart from other portable particle monitors on the market. Operating the device is as simple as pressing the start button and turning the dial. The test procedure is automatic and takes no more than 2 minutes to complete.
An iCount LaserCM Aggressive Fluids model is available for monitoring corrosive fluids, such as phosphate ester based lubricants used in commercial aviation. Also available are the Parker iCountPD for inline continuous particle detection, and the iCountOS.
For additional information, consult the iCount LaserCM documentation in the “Product Support” tab.
Markets:
•Agriculture
•Construction
•Oil and Gas
•Power Generation
•Marine
•Mining
•Forestry
•Industrial Plant
•Aviation

Applications:

•Deck and mobile cranes
•Firefighting equipment
•Forwarders
•Hydraulic presses
•Marine steering units
•Power packs
•Waste management, dump and fork lift trucks
•Excavators
•Harvesters
•Waste balers
•Reach stackers
•Wheeled loaders
•Drilling equipment
•Industrial power units
•Airplanes

Benefits:
•Provides field service personnel with the capability to quickly and easily measure the contamination level of hydraulic fluid or oil in industrial equipment. Dirty fluid can then be replaced and/or cleansed, leading to improved system performance and efficiency.
•Compact, portable design provides ease of use in the field, as well as in the laboratory
•Particle monitor can be utilized while machinery is in operation, ensuring system uptime
•Comes equipped with a variety of intuitive features to accommodate users unique requirements, including ISO/AS/NAS standard cleanliness reporting, data entry and graphing, built-in memory storage, and an integral printer

Features:
•Capable of connecting to flows up to 400 L/min (105 GPM) when used with system 20 Sensors. Higher with single point sampler
•Maximum working pressure: 420 bar (6000 psi)
•Particle counts: MTD 4+, 6+, 14+, 21+, 38+ and 70+ microns(c), ACFTD 2+, 5+, 15+, 25+, 50+ and 100+ microns
•Computer compatibility: Interface via RS232 connection @ 9600 baud rate.
•Automatic test cycle logging of up to 300 tests can be selected via hand set display.
•2 minute test cycle
•Data entry allows individual equipment footprint record.
•Data graphing selectable via the integral printer. Auto 300-test cycle logging via LCD handset input
•Limit level output to control peripheral equipment such as off-line filtration via internal relay limit switches
•Auto-testing allows for the conducting of automatic sequencing tests on flushing systems for example
•Optional bar code swipe wand to allow handset data loading
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSignal OutputMinimum Fluid TemperatureWidthStatic Memory OptionHeightTechnologyOperating PressureElectrical RequirementsWeightCycle TimeDivisionIndustryElectrical ConnectionSensing MethodLengthMaximum Fluid TemperatureDivisionBrandPort SizeProduct TypeProduct StyleFor Fluid TypeBody MaterialSpecifications MetFlow RateOperating TemperatureMaterials of ConstructionSeal MaterialAccuracyPort TypeCommunication InterfaceFor Fluid TypeCalibration TypeSeal MaterialOptions
LCM202021
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial Manufacturing Equipment12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPetroleum-based FuelBrassCE Certification4005 to 40ABS Structure FoamFluorocarbon< 7MetricUSB PortPetroleum-based FuelACFTDFluorocarbonno
LCM202022
Quote Required
TBD
Display41 °F158 mm300277 mmFiltration6000 psi110 to 240 VAC8 kg< 2 minHydraulic & Industrial Process Filtration Division EMEAIndustrial Manufacturing Equipment12VDC Power SupplyLaser240 mm176 °FHydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterMineral-based OilsStainless SteelCE Certification400 L/min41 to 104 °FABS Structure FoamFluorocarbon< 7 %MetricUSB PortPetroleum-based FuelMTDFluorocarbonno
LCM202025
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPetroleum-based FuelBrassCE Certification4005 to 40ABS Structure FoamFluorocarbon< 7MetricUSB PortPetroleum-based FuelACFTDFluorocarbonClassic
LCM202026
Quote Required
TBD
Display41 °F158 mm300277 mmFiltration2 to 420 bar110 to 240 VAC8 kg< 2 minHydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser240 mm80 °CHydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterMineral-based OilsBrassCE Certification400 L/min41 to 104 °FABS Structure FoamFluorocarbon< 7 %MetricUSB PortPetroleum-based FuelMTDFluorocarbonClassic
LCM202027
Quote Required
TBD
Display41 °F158 mm300277 mmFiltration29 to 6000 psi110 to 240 VAC8 kg< 2 minHydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser240 mm80 °CHydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPetroleum-based FuelStainless SteelCE Certification400 L/min5 to 40 °CABS Structure FoamFluorocarbon< 7 %MetricUSB PortPetroleum-based FuelACFTDFluorocarbonWith CMP
LCM202028
Quote Required
TBD
Display41 °F158 mm300277 mmFiltration2 to 420 bar110 to 240 VAC8 kg< 2 minHydraulic & Industrial Process Filtration Division EMEAOil and Gas12VDC Power SupplyLaser240 mm80 °CHydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPetroleum-based FuelStainless SteelCE Certification400 L/min5 to 40 °CABS Structure FoamFluorocarbon< 7 %MetricUSB PortPetroleum-based FuelMTDFluorocarbonWith CMP
LCM202061
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial Manufacturing Equipment12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification4005 to 40ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)ACFTDPerfluoroelastomerno
LCM202061US
Quote Required
TBD
Display41158300277Hydraulics29 to 6000110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial Manufacturing Equipment12VDC Power SupplyLaser240176Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)Stainless SteelCE Certification40041 to 104ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)ACFTDPerfluoroelastomerno
LCM202062
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial Manufacturing Equipment12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification4005 to 40ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)MTDPerfluoroelastomerno
LCM202062US
Quote Required
TBD
Display5 °C158 mm300277 mmFiltration2 to 420 bar110 to 240 VAC8 kg< 2 minHydraulic & Industrial Process Filtration Division EMEAIndustrial Manufacturing Equipment12VDC Power SupplyLaser240 mm80 °CHydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification400 L/min5 to 40 °CABS Structure FoamPerfluoroelastomer< 7 %MetricUSB PortPhosphate Esters (Skydrol)MTDPerfluoroelastomerno
LCM202065
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification4005 to 40ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)ACFTDPerfluoroelastomerClassic
LCM202066
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification4005 to 40ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)MTDPerfluoroelastomerClassic
LCM202067
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification4005 to 40ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)ACFTDPerfluoroelastomerWith CMP
LCM202068
Quote Required
TBD
Display5158300277Filtration2 to 420110 to 2408< 2Hydraulic & Industrial Process Filtration Division EMEAIndustrial & Chemical Processing12VDC Power SupplyLaser24080Hydraulic & Industrial Process Filtration Division EMEAParkerM16Condition MonitorParticle Detector/CounterPhosphate Esters (Skydrol)BrassCE Certification4005 to 40ABS Structure FoamPerfluoroelastomer< 7MetricUSB PortPhosphate Esters (Skydrol)MTDPerfluoroelastomerWith CMP