• Availability & Price
  • Search SKU
Filter by attributes
  • Filter Included
  • Flow Rate
  • Maximum Working Viscosity
  • Options
More Filters...
Filter by manufacturer
Manufacturers

Portable Filtration Unit - GLFTrolley

Picture for category Portable Filtration Unit - GLFTrolley

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Hydraulic or lubricating oil fluid should always be filtered before being put into use. New fluids are not necessarily clean. Most new fluids (right out of the drum or container) are unfit for use due to high initial contamination levels. Contamination may be added to a new fluid during processing, mixing, handling and storage.

The Parker GLFTrolley is CE marked and fully compliant with the following directives: EU Machinery Directive (MD) (2006/42/EC), Electromagnetic Compatibility Directive (EMC) (2014/30/EU) and The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC.

The Parker GLFTrolley units are available with two flow options:
• 40 l/min for normal viscosity fluids (up to 250cSt oil at operating temperature)
• 20 l/min for high viscosity fluids (up to 400cSt at operating temperature)

Filtration in the GLFTrolley is based on the top loaded GLF iProtect® return line filter minimizing the spillage during element change. GLF iProtect® filters have patented element construction maximizing the dirt holding capacity and efficiency offering several filtration grades. The standard filter element fineness is 10 micron with bypass setting of 3.5bar. For other filter element options please contact your local Parker representative or see product catalogue. The filter is equipped with visual pressure gauge to monitor the condition of the element during the operation.

GLFTrolley is equipped with removable drip tray to secure safe and clean operation.

Units include the cords with both EU and UK type electrical plug.

The GLFTrolley is available with 3-way valve to allow bypassing the filter when empty the reservoir from used oil reducing the need of replacing the element. This option is available for both flow rate versions.

As an option GLFTrolley is also available with iPD particle detection unit for enhanced monitoring of the hydraulic system. The max viscosity for the unit with iPD mounted is limited to 108cSt.

GLFTrolleys without particle detector have 850 micron pre-filter to protect the pump from bigger particles. The units with particle detection unit have finer prefilter with 125 micron mounted.

Applications:
• Filtering new fluid before using
• Transferring fluid from storage tanks to system reservoirs
• Conditioning system fluid
• For use with hydraulic and lube oils

Standard unit includes:
• Top-accessible service cover for easy changing of elements
• Assembled hose kits and wands with chamfered end offering reliable suction capability
• Balanced heavy duty frame with industrial designed wheels
• Parker gear pump with internal safety relief valve offering reliable fluid transfer maximizing the operating pressure to 10 bar
• GLF iProtect(R) filter elements designed for high dirt holding capacity and efficient contamination removal levels
• Visual indicator included to notify user for element change
• Both EUR and UK type plug electrical cords included

Fully compliant CE certification according to directives:
• EU Machinery Directive (MD) (2006/42/EC)
• Electromagnetic Compatibility Directive (EMC) (2014/30/EU)
• The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionDivisionProduct TypeMaximum Operating PressureWidthHeightMicron RatingFor Fluid TypeProduct SeriesSpecifications MetDepthWeightInput VoltageOperating AltitudeAmbient TemperatureElectrical ConnectionBypass Option IncludedIngress Protection RatingMaximum Fluid TemperatureOptionsFlow RateFilter IncludedMaximum Working Viscosity
GLFT2010QIB3WN
Quote Required
TBD
ParkerFiltrationHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulic Filter10 bar560 mm1300 mmStage 1: 850 μm<br/>Stage 2: 10 μmMineral and synthetic oilsGLFTrolleyMachinery Directive (MD) (2006/42/EC)<br/><br/>Electromagnetic Compatibility Directive (EMC) (2014/30/EU)<br/><br/>The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC<br/><br/>610 mm68 kg230 V0 to 500 m0°C to 45°CPlug: EU (Type F) and UK (Type G)Main filter bypass valveIP55Max 70°C (Minimum temperature acc. to maximum working viscosity)3-Way Valve20 L/minInlet: 850 μm - Outlet: 10 μm400 cSt
GLFT2010QIBNN
Quote Required
TBD
ParkerFiltrationHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulic Filter10 bar560 mm1300 mmStage 1: 850 μm<br/>Stage 2: 10 μmMineral and synthetic oilsGLFTrolleyMachinery Directive (MD) (2006/42/EC)<br/><br/>Electromagnetic Compatibility Directive (EMC) (2014/30/EU)<br/><br/>The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC<br/><br/>610 mm62 kg230 V0 to 500 m0°C to 45°CPlug: EU (Type F) and UK (Type G)NoIP55Max 70°C (Minimum temperature acc. to maximum working viscosity)None20 L/minInlet: 850 μm - Outlet: 10 μm400 cSt
GLFT4010QIB3WIPD
Quote Required
TBD
ParkerFiltrationHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulic Filter10 bar530 mm1260 mmStage 1: 125 μm<br/>Stage 2: 10 μmMineral and synthetic oilsGLFTrolleyMachinery Directive (MD) (2006/42/EC)<br/><br/>Electromagnetic Compatibility Directive (EMC) (2014/30/EU)<br/><br/>The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC<br/><br/>750 mm73 kg230 V0 to 500 m0°C to 45°CPlug: EU (Type F) and UK (Type G)Main filter bypass valveIP55Max 70°C (Minimum temperature acc. to maximum working viscosity)iPD40 l/minInlet: 125 μm - Outlet: 10 μm108 cSt
GLFT4010QIB3WN
Quote Required
TBD
ParkerFiltrationHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulic Filter10 bar600 mm1300 mmStage 1: 850 μm<br/>Stage 2: 10 μmMineral and synthetic oilsGLFTrolleyMachinery Directive (MD) (2006/42/EC)<br/><br/>Electromagnetic Compatibility Directive (EMC) (2014/30/EU)<br/><br/>The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC<br/><br/>610 mm70 kg230 V0 to 500 m0°C to 45°CPlug: EU (Type F) and UK (Type G)Main filter bypass valveIP55Max 70°C (Minimum temperature acc. to maximum working viscosity)3-Way Valve40 l/minInlet: 850 μm - Outlet: 10 μm250 cSt
GLFT4010QIBNN
Quote Required
TBD
ParkerFiltrationHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulic Filter10 bar600 mm1300 mmStage 1: 850 μm<br/>Stage 2: 10 μmMineral and synthetic oilsGLFTrolleyMachinery Directive (MD) (2006/42/EC)<br/><br/>Electromagnetic Compatibility Directive (EMC) (2014/30/EU)<br/><br/>The Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC<br/><br/>610 mm64 kg230 V0 to 500 m0°C to 45°CPlug: EU (Type F) and UK (Type G)NoIP55Max 70°C (Minimum temperature acc. to maximum working viscosity)None40 l/minInlet: 850 μm - Outlet: 10 μm250 cSt