• Availability & Price
  • Search SKU
Filter by attributes
  • Adjustment Type
  • Cracking Pressure (psi)
  • Drain Option
  • Pilot Option
  • Pressure Range Adjustment (psi)
  • Rated Flow (gpm)
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Pilot Operated Sequence Valves

Picture for category Pilot Operated Sequence Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of pilot operated sequence valves provide superior stability and are designed for sequenced applications with pressures up to 380 bar (5500 psi) and flows up to 152 lpm (40 gpm) in a variety of sizes. The variety of pressure adjustment styles and piloted or vented controls makes these valves an ideal solution for controlling multiple circuit sections that operate at different pressure settings. Normally-open and normally-closed valves are available in a 2 position 2-way configuration and can be either internally or externally drained depending on application needs. These pilot operated sequence valves can be used within clamping circuits or high/low system applications within several industrial and mobile markets.

Markets:
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High pressure and flow capacity
• Internal screens for pilot spring protection
• Low profile designs
• Hardened, precision ground parts for durability
• All external parts zinc plated

Applications:
• Dump circuits
• High/low systems
• Sequencing applications

Additional Technical Insight:
SVH081, SVH101, and SVH161 pilot operated sequence valves are internally piloted and externally drained.  All three versions are normally closed spool-type valves that prevent flow from passing through the valve until the adjustable pressure setting is reached.  When the inlet pressure exceeds the sequence setting the valve is internally piloted open allowing flow downstream to a secondary function.  An external drain port plumbed directly to tank ensures that downstream pressure does not affect the pressure setting.  Clamp and machine, or unlock and dump, are typical applications since they require one function to happen before another one.

SVH102 and SVH162 are externally piloted and internally drained sequence valves.  Both are normally closed and prevent flow from passing through the valve when the pilot pressure is below the pressure setting.  When the external pilot source exceeds the adjustable pressure setting, the valve opens allowing flow to go downstream.  Back pressure on the downstream port is added to the valve setting due to the internal drain, therefore it is most common to connect the sequenced port to tank.  High-Low Pump Unloading is a common application.

SVCH101 is an inline mounted combination of an internally piloted, externally drained sequence valve and a reverse flow check.  An SVH101 sequence valve and a CVH103 check valve are incorporated into a single body with SAE-8 work ports and an SAE-6 drain.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialPort SizeBody MaterialMinimum Operating TemperatureDivisionDivisionPilot LocationMaximum Kinematic ViscosityWeightMaximum Operating PressureActuation TypeAdjustment MechanismMaximum Tank PressureCracking PressureFunctionCavity SizeDrain OptionFlow RateMaximum Flow RateMounting TypeMaximum Inlet Pressure RatingFor Fluid TypeValve MaterialFilter Efficiency RatingOperating TemperatureMaximum Operating TemperatureInstallation TorqueStandard Setting PressureMaximum Pressure SettingPressure Control RangeMaximum Drain Flow RatePressure Control SensitivityLeak RateReseat PressureSeal MaterialPilot OptionDrain OptionRated Flow (gpm)Cracking Pressure (psi)Pressure Range Adjustment (psi)Adjustment Type
SVH081T20N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25032-3610002000100-20000.15570 per turn82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal12N/A100-2000Tamper Resistant
SVH081T20V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40032-3610002000100-20000.15570 per turn82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal12N/A100-2000Tamper Resistant
SVH081T30
Quote Required
TBD
D-Ring (Standard)n/an/a-35Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+20032-3615003000200-30000.15859 per turn82 @ 3000 PSI (210 BAR)90% of set pressureD-Ring (Standard)InternalExternal12N/A200-3000Tamper Resistant
SVH081T30N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25032-3615003000200-30000.15859 per turn82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal12N/A200-3000Tamper Resistant
SVH081T30V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40032-3615003000200-30000.15859 per turn82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal12N/A200-3000Tamper Resistant
SVH081T50
Quote Required
TBD
D-Ring (Standard)n/an/a-35 °FHydraulic Cartridge Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.25 lb380 barPressure SensingTamper Resistant5000 psiN/A barPilot Operated SequenceC08-3External12 Gal/min12 Gal/minThreaded Cartridge Valve380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200 °F+93 °C32-36 lb-ft172.4 bar350 bar200-5000 psi0.56 L/min1910 per turn psi82 @ 3000 PSI (210 BAR) cm3/min90% of set pressureD-Ring (Standard)InternalExternal12N/A200-5000Tamper Resistant
SVH081T50N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25032-3625005000200-50000.151910 per turn82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal12N/A200-5000Tamper Resistant
SVH081T50V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)0.255500Pressure SensingTamper Resistant5000n/aPilot Operated SequenceC08-3External1212Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40032-3625005000200-50000.151910 per turn82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal12N/A200-5000Tamper Resistant
SVH101F10
Quote Required
TBD
D-Ring (Standard)n/an/a-35Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+20051-555001000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureD-Ring (Standard)InternalExternal15N/AN/AFixed
SVH101F10N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25051-555001000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal15N/AN/AFixed
SVH101F10V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40051-555001000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal15N/AN/AFixed
SVH101F20
Quote Required
TBD
D-Ring (Standard)n/an/a-35Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+20051-5510002000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureD-Ring (Standard)InternalExternal15N/AN/AFixed
SVH101F20N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25051-5510002000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal15N/AN/AFixed
SVH101F20V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40051-5510002000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal15N/AN/AFixed
SVH101F30
Quote Required
TBD
D-Ring (Standard)n/an/a-35Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+20051-5515003000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureD-Ring (Standard)InternalExternal15N/AN/AFixed
SVH101F30N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25051-5515003000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal15N/AN/AFixed
SVH101F30V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40051-5515003000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal15N/AN/AFixed
SVH101F50
Quote Required
TBD
D-Ring (Standard)n/an/a-35Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+20051-5525005000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureD-Ring (Standard)InternalExternal15N/AN/AFixed
SVH101F50N
Quote Required
TBD
Nitrilen/an/a-30Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+25051-5525005000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureNitrileInternalExternal15N/AN/AFixed
SVH101F50V
Quote Required
TBD
Fluorocarbonn/an/a-15Hydraulic Valve Systems DivisionHydraulic Systems DivisionInternal45-2000 SSU (6 to 420 cSt)15500Pressure SensingFixed5000n/aPilot Operated SequenceC10-3External1515Threaded Cartridge Valve5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+40051-5525005000n/a0.94n/a82 @ 3000 PSI (210 BAR)90% of set pressureFluorocarbonInternalExternal15N/AN/AFixed