Pilot Operated Directional Control Valve - D31DW, D31VW Series

Picture for category Pilot Operated Directional Control Valve - D31DW, D31VW Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D31 directional control valves are suitable for manifold or subplate mounting. These valves conform to NFPA’s D05, CETOP 5 and D05HE, CETOP 5H mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Mounting bolts below center line of spool minimizes spool binding
• Five chamber style eliminates pressure spikes in tubes, increasing valve life
• High pressure & flow ratings provide increased performance options in a compact valve

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMConnection TypeAdditional OptionsMinimum Operating TemperatureSeal MaterialOptionsWeightSpool PositionDivisionSolenoid OptionBody MaterialMaximum Flow RateMounting TypeSpool CodeMaximum Operating TemperatureValve TypeCoil Specifications MetPilot Inlet / Drain LocationsActuation TypePower Supply VoltageMaximum Operating PressureMounting TypeMaximum Operating PressureSizeMaximum Flow Rate
D31VW020B4VJW
Quote Required
$976.50
EADIN w/o PlugConsult catalog for additional features.-4FluorocarbonOmit12Single SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure245000Subplate5574 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VJW.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4FluorocarbonOmit12Single SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure245000Subplate5574 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VYGF5
Quote Required
TBD
Plug-in Conduit BoxConsult catalog for additional features.-4FluorocarbonSignal Lights12Single SolenoidHydraulic Valve Systems DivisionLow WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure120/60 - 110/50 VAC5000Subplate5575 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VYGF5.
Quote Required
TBD
Plug-in Conduit BoxConsult catalog for additional features.-4FluorocarbonSignal Lights12Single SolenoidHydraulic Valve Systems DivisionLow WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure120/60 - 110/50 VAC5000Subplate5575 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VYGF56
Quote Required
TBD
Plug-in Conduit BoxConsult catalog for additional features.-4FluorocarbonManaplug (Mini) with Lights12Single SolenoidHydraulic Valve Systems DivisionLow WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure120/60 - 110/50 VAC5000Subplate5576 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VYGF56.
Quote Required
TBD
Plug-in Conduit BoxConsult catalog for additional features.-4FluorocarbonManaplug (Mini) with Lights12Single SolenoidHydraulic Valve Systems DivisionLow WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure120/60 - 110/50 VAC5000Subplate5576 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VYWF
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4FluorocarbonOmit12Single SolenoidHydraulic Valve Systems DivisionLow WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure120/60 - 110/50 VAC5000Subplate5577 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B4VYWF.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4FluorocarbonOmit12Single SolenoidHydraulic Valve Systems DivisionLow WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / Internal DrainHydraulic Pressure120/60 - 110/50 VAC5000Subplate5577 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B5NJW
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12Single SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitExternal Pilot / Internal DrainHydraulic Pressure245000Subplate5578 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B5NJW.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12Single SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitExternal Pilot / Internal DrainHydraulic Pressure245000Subplate5578 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B5NJWL3A
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrilePilot Choke Meter-out12Single SolenoidHydraulic Valve Systems DivisionHigh Watt (standard)Gray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitExternal Pilot / Internal DrainHydraulic Pressure245000Subplate5579 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B5NJWL3A.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrilePilot Choke Meter-out12Single SolenoidHydraulic Valve Systems DivisionHigh Watt (standard)Gray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitExternal Pilot / Internal DrainHydraulic Pressure245000Subplate5579 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B5NUW
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12P to A and B to T in Offset Position.Hydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitExternal Pilot / Internal DrainHydraulic Pressure985000Subplate5580 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020B5NUW.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12P to A and B to T in Offset Position.Hydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitExternal Pilot / Internal DrainHydraulic Pressure985000Subplate5580 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020D1NJP5
Quote Required
TBD
DIN with PlugConsult catalog for additional features.-4NitrileSignal Lights12Double SolenoidHydraulic Valve Systems DivisionHigh Watt (standard)Gray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / External DrainHydraulic Pressure245000Subplate5581 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020D1NJP5.
Quote Required
TBD
DIN with PlugConsult catalog for additional features.-4NitrileSignal Lights12Double SolenoidHydraulic Valve Systems DivisionHigh Watt (standard)Gray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / External DrainHydraulic Pressure245000Subplate5581 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020D1NJW
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12Double SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / External DrainHydraulic Pressure245000Subplate5582 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020D1NJW.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12Double SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / External DrainHydraulic Pressure245000Subplate5582 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020D1NKW
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12Double SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / External DrainHydraulic Pressure12 VDC5000Subplate5583 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min
D31VW020D1NKW.
Quote Required
TBD
DIN w/o PlugConsult catalog for additional features.-4NitrileOmit12Double SolenoidHydraulic Valve Systems DivisionOmit - High WattGray Iron40Subplate4-Way140Pilot Operated Directional Control ValveOmitInternal Pilot / External DrainHydraulic Pressure12 VDC5000Subplate5583 psi/ 345 barNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min