• Availability & Price
  • Search SKU
Filter by attributes
  • Materials of Construction
  • Options
  • Specifications Met
  • Tube Outside Diameter
More Filters...
Filter by manufacturer
Manufacturers

Parker Tube Fitting, Union - A-LOK Series

Picture for category Parker Tube Fitting, Union - A-LOK Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's two ferrule compression fittings, A-LOK® Union Tube Fittings are designed to provide reliable leak-free connections for instrumentation, process and control, and analyzer applications that specify a two ferrule tube fitting connection. Manufactured to the highest quality standards these tube fittings are available in a broad range of sizes, corrosion resistant materials and configurations.

As standard, Parker’s A-LOK®Union Tube Fittings are manufactured from heat code traceable 316 stainless steel. Other materials include 6Mo, Alloy 825, Alloy 625 and Alloy C-276.

The fittings are available for fractional pipe sizes from 1/16” through to 2” O.D., and for metric sizes from 2 mm through to 32 mm O.D.

Markets:
• Semiconductor/Microelectronics
• Chemical
• Petro-Chemical
• Transportation
• Power
• Nuclear
• Oil and Gas
• Research Labs

Features/Benefits:
• Wide range of Corrosion Resistant Alloys available
• EC79 Approved for Hydrogen Service
• Parker Suparcase™ surface treatment process for superior material hardening
• Hardened ferrules provide leak free connections
• Silver plated nuts provide gall resistance during makeup

Applications:
• Instrumentation Hook-up Systems
• Analytical Installations
• CNG / LNG Lines
• Hydrogen Service
• Offshore Control Panels
• Sensing Lines
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceFor Fluid TypeIndustryShapeDivisionTechnologyConfigurationLengthDivisionMinimum Operating TemperatureOperating PressureMaximum Operating TemperatureBrandApplicationTube Outside DiameterOptionsMaterials of ConstructionSpecifications Met
SCM15-825
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198170 to 400426A-LOKAnalytical Installations15 mm (O.D.)n/aAlloy 825N/A
SCM15-825-NC
Quote Required
TBD
CorrosiveMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198170 to 400426A-LOKAnalytical Installations15 mm (O.D.)n/aAlloy 825NACE
SCM15-B
Quote Required
TBD
CorrosiveNuclearStraightInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-170 to 400 bar-A-LOKCNG / LNG Lines15 mm (O.D.)n/aBrassN/A
SCM15-IIY
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198170 to 400649A-LOKAnalytical Installations15 mm (O.D.)n/aAlloy 625N/A
SCM15-IIY-NC
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198170 to 400649A-LOKAnalytical Installations15 mm (O.D.)n/aAlloy 625NACE
SCM15-M
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198170 to 400425A-LOKAnalytical Installations15 mm (O.D.)n/aMonel 400N/A
SCM15-M-NC
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198170 to 400425A-LOKAnalytical Installations15 mm (O.D.)n/aMonel 400NACE
SCM15-NNR
Quote Required
TBD
Petroleum OilSemiconductorUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-198 °C170 to 400 bar535 °CA-LOKHydrogen Service15 mm (O.D.)n/aAlloy C-276N/A
SCM15-NNR-NC
Quote Required
TBD
FuelsPetrochemicalUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-198 °C170 to 400 bar535 °CA-LOKHydrogen Service15 mm (O.D.)n/aAlloy C-276NACE
SCM15-S
Quote Required
TBD
SteamMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-170 to 400-A-LOKAnalytical Installations15 mm (O.D.)n/aSteelN/A
SCM15-S-NC
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-170 to 400-A-LOKAnalytical Installations15 mm (O.D.)n/aSteelNACE
SCM15-TTZ
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-59170 to 400315A-LOKAnalytical Installations15 mm (O.D.)n/aTitaniumN/A
SCM15-TTZ-NC
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-59170 to 400315A-LOKAnalytical Installations15 mm (O.D.)n/aTitaniumNACE
SCM16-316
Quote Required
TBD
OilPower GenerationUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-255 °C190 to 430 bar649 °CA-LOKCNG / LNG Lines16 mm (O.D.)n/aStainless Steel AISI 316N/A
SCM16-316L
Quote Required
TBD
OilPower GenerationUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-190 to 430 bar-A-LOKSensing Lines16 mm (O.D.)n/aStainless Steel AISI 316LN/A
SCM16-316-NC
Quote Required
TBD
LiquidMicroelectronicsUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-255190 to 430649A-LOKAnalytical Installations16 mm (O.D.)n/aStainless Steel AISI 316NACE
SCM16-6MO
Quote Required
TBD
GasesChemicalUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-198 °C190 to 430 bar371 °CA-LOKAnalytical Installations16 mm (O.D.)n/a6MoN/A
SCM16-6MONC
Quote Required
TBD
OilTransportationStraightInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-198 °C190 to 430 bar371 °CA-LOKAnalytical Installations16 mm (O.D.)n/a6MoNACE
SCM16-6MO-NC-NSK
Quote Required
TBD
LiquidSemiconductorUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52Instrumentation Products Division-198190 to 430371A-LOKAnalytical Installations16 mm (O.D.)n/a6MoNACE
SCM16-6MO-NSK
Quote Required
TBD
Petroleum OilChemicalUnionInstrumentation Products DivisionProcess ControlTube to Tube (Union)52 mmInstrumentation Products Division-198 °C190 to 430 bar371 °CA-LOKInstrumentation16 mm (O.D.)n/a6MoNORSOK M650