Products specifications
Attribute nameAttribute value
Seal MaterialNitrilePort Sizen/a
Body Materialn/aMaximum Operating Pressure5500 psi
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationInternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-34 °CMaximum Flow Rate40 Gal/min
Actuation TypePressure SensingMaximum Pressure Setting210 bar
Adjustment MechanismTamper ResistantMaximum Tank Pressure5000 psi
Weight1 lbFunctionPilot Operated Sequence
Drain OptionExternalMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating5500 psiInstallation Torque73 lb-ft
Maximum Operating Temperature+121 °CFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-30 to +250 °F
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Standard Setting Pressure1500 psi
Cracking PressureN/A psiPressure Control Range300-3000 psi
Leak Rate5 per 100 psi (6.8 bar) setting cm3/minPressure Control Sensitivity867 per turn psi
Flow Rate151.6 L/minCavity Size6-3
Reseat Pressure80% of set pressureMaximum Drain Flow Rate1.87 Gal/min
Seal MaterialNitrilePilot OptionInternal
Drain OptionExternalCracking Pressure (psi)N/A
Adjustment TypeTamper ResistantRated Flow (gpm)40
Pressure Range Adjustment (psi)300-3000