Parker SVH161S10V - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH161S10V
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Port Sizen/aSeal MaterialFluorocarbon
Body Materialn/aDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionPilot LocationInternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-15 °F
Actuation TypePressure SensingAdjustment MechanismScrew
Maximum Tank Pressure350 barFunctionPilot Operated Sequence
Drain OptionExternalWeight0.45 kg
Mounting TypeThreaded Cartridge ValveMaximum Inlet Pressure Rating380 bar
Installation Torque99 NmMaximum Operating Temperature+400 °F
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-26 to +204 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Maximum Operating Pressure380 barMaximum Pressure Setting1000 psi
Standard Setting Pressure34.5 barCracking PressureN/A psi
Pressure Control Range6.9-69 barPressure Control Sensitivity23 per turn bar
Leak Rate5 per 100 psi (6.8 bar) setting cm3/minFlow Rate151.6 L/min
Cavity Size6-3Reseat Pressure80% of set pressure
Maximum Flow Rate151.6 L/minMaximum Drain Flow Rate1.87 Gal/min
Seal MaterialFluorocarbonPilot OptionInternal
Drain OptionExternalAdjustment TypeScrew
Cracking Pressure (psi)N/APressure Range Adjustment (psi)100-1000
Rated Flow (gpm)40
Product resources