Parker SVH161S10 - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH161S10
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrilePort Sizen/a
Body Materialn/aMaximum Operating Pressure5500 psi
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationInternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-34 °CActuation TypePressure Sensing
Adjustment MechanismScrewMaximum Tank Pressure5000 psi
Weight1 lbFunctionPilot Operated Sequence
Drain OptionExternalMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating380 barInstallation Torque99 Nm
Flow Rate40 Gal/minMaximum Operating Temperature+250 °F
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-30 to +250 °FFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Maximum Pressure Setting69 barStandard Setting Pressure34.5 bar
Pressure Control Range6.9-69 barPressure Control Sensitivity23 per turn bar
Leak Rate5 per 100 psi (6.8 bar) setting cm3/minCracking PressureN/A bar
Maximum Drain Flow Rate0.5 L/minCavity Size6-3
Reseat Pressure80% of set pressureMaximum Flow Rate151.6 L/min
Seal MaterialNitrilePilot OptionInternal
Drain OptionExternalAdjustment TypeScrew
Cracking Pressure (psi)N/APressure Range Adjustment (psi)100-1000
Rated Flow (gpm)40