Parker SVH102T50 - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH102T50
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Port Sizen/aBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationExternalMaximum Flow Rate15 Gal/min
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-35 °F
Actuation TypePressure SensingAdjustment MechanismTamper Resistant
Maximum Tank Pressure350 barMaximum Pressure Setting5000 psi
Seal MaterialD-Ring (Standard)FunctionPilot Operated Sequence
Cavity SizeC10-3Drain OptionInternal
Weight0.45 kgMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating380 barFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Operating Temperature-37 to +93 °CMaximum Operating Temperature+93 °C
Installation Torque51-55 lb-ftMaximum Operating Pressure380 bar
Flow Rate56.3 L/minStandard Setting Pressure172.4 bar
Pressure Control Sensitivity1910 per turn psiCracking PressureN/A psi
Pressure Control Range13.8-350 barLeak Rate82 @ 3000 PSI (210 BAR) cm3/min
Reseat Pressure90% of set pressureMaximum Drain Flow Rate0.5 L/min
Seal MaterialD-Ring (Standard)Cracking Pressure (psi)N/A
Pressure Range Adjustment (psi)200-5000Drain OptionInternal
Pilot OptionExternalAdjustment TypeTamper Resistant
Rated Flow (gpm)15