Parker SVH101T10 - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH101T10
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Port Sizen/aBody Materialn/a
Maximum Operating Pressure5500 psiDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionFlow Rate15 Gal/min
Pilot LocationInternalMaximum Flow Rate15 Gal/min
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-37 °C
Maximum Operating Temperature+200 °FActuation TypePressure Sensing
Adjustment MechanismTamper ResistantMaximum Tank Pressure5000 psi
Seal MaterialD-Ring (Standard)FunctionPilot Operated Sequence
Cavity SizeC10-3Drain OptionExternal
Weight0.45 kgMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating5500 psiFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Operating Temperature-37 to +93 °CInstallation Torque51-55 lb-ft
Maximum Pressure Setting1000 psiStandard Setting Pressure34.5 bar
Cracking PressureN/A psiPressure Control Range6.9-69 bar
Pressure Control Sensitivity285 per turn psiLeak Rate82 @ 3000 PSI (210 BAR) cm3/min
Reseat Pressure90% of set pressureMaximum Drain Flow Rate0.94 Gal/min
Seal MaterialD-Ring (Standard)Pilot OptionInternal
Drain OptionExternalCracking Pressure (psi)N/A
Adjustment TypeTamper ResistantRated Flow (gpm)15
Pressure Range Adjustment (psi)300-1000