Parker SVH101S50V - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
AFP Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH101S50V
$105.00/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEABody MaterialN/A
Mounting TypeThreaded Cartridge ValveStandard Setting Pressure172.4 bar
Maximum Drain Flow Rate0.25 L/minMaximum Flow Rate15 Gal/min
Leak Rate82 @ 3000 PSI (210 BAR) cm3/minPort SizeN/A
Reseat Pressure90% of set pressureFlow Rate15 Gal/min
Drain OptionExternalDivisionHydraulic Systems Division
Pilot LocationInternalOperating Temperature-15 to +400 °F
Installation Torque51-55 lb-ftMinimum Operating Temperature-15 °F
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Maximum Pressure Setting5000 psi
Maximum Inlet Pressure Rating5500 psiAdjustment MechanismScrew
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Valve MaterialAll parts steel. All operating parts hardened steel
Cracking PressureN/A psiActuation TypePressure Sensing
Seal MaterialFluorocarbonWeight1 lb
Maximum Operating Pressure380 barPressure Control Range200-5000 psi
Maximum Operating Temperature+204 °CCavity SizeC10-3
DivisionHydraulic Cartridge Systems DivisionFunctionPilot Operated Sequence
Maximum Tank Pressure5000 psiFor Fluid TypeMineral-based or synthetic hydraulic fluids
Pressure Control Sensitivity131.7 per turn barSeal MaterialFluorocarbon
Pilot OptionInternalDrain OptionExternal
Adjustment TypeScrewCracking Pressure (psi)N/A
Pressure Range Adjustment (psi)200-5000Rated Flow (gpm)15
Product resources