Parker SVH101S50V - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH101S50V
$77.25
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAPort Sizen/a
Seal MaterialFluorocarbonBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Flow Rate15 Gal/minPilot LocationInternal
Maximum Flow Rate15 Gal/minMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-15 °FActuation TypePressure Sensing
Adjustment MechanismScrewMaximum Tank Pressure5000 psi
Maximum Pressure Setting5000 psiWeight1 lb
FunctionPilot Operated SequenceCavity SizeC10-3
Drain OptionExternalMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating5500 psiMaximum Operating Temperature+204 °C
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-15 to +400 °FFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Installation Torque51-55 lb-ftMaximum Operating Pressure380 bar
Standard Setting Pressure172.4 barPressure Control Sensitivity131.7 per turn bar
Cracking PressureN/A psiPressure Control Range200-5000 psi
Leak Rate82 @ 3000 PSI (210 BAR) cm3/minReseat Pressure90% of set pressure
Maximum Drain Flow Rate0.25 L/minSeal MaterialFluorocarbon
Pilot OptionInternalDrain OptionExternal
Adjustment TypeScrewCracking Pressure (psi)N/A
Pressure Range Adjustment (psi)200-5000Rated Flow (gpm)15
Product resources