Parker SVH101S10V - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH101S10V
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Port Sizen/aSeal MaterialFluorocarbon
Body Materialn/aMaximum Operating Pressure5500 psi
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationInternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-26 °CActuation TypePressure Sensing
Adjustment MechanismScrewMaximum Tank Pressure350 bar
FunctionPilot Operated SequenceCavity SizeC10-3
Drain OptionExternalWeight0.45 kg
Mounting TypeThreaded Cartridge ValveMaximum Inlet Pressure Rating5500 psi
Maximum Operating Temperature+400 °FFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-26 to +204 °C
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Installation Torque51-55 lb-ft
Flow Rate56.3 L/minMaximum Flow Rate56.3 L/min
Maximum Pressure Setting1000 psiStandard Setting Pressure500 psi
Pressure Control Sensitivity19.6 per turn barPressure Control Range6.9-69 bar
Leak Rate82 @ 3000 PSI (210 BAR) cm3/minReseat Pressure90% of set pressure
Cracking PressureN/A barMaximum Drain Flow Rate0.25 L/min
Seal MaterialFluorocarbonPilot OptionInternal
Drain OptionExternalAdjustment TypeScrew
Cracking Pressure (psi)N/ARated Flow (gpm)15
Pressure Range Adjustment (psi)300-1000
Product resources