Parker SVH101K30 - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH101K30
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Port Sizen/aBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Flow Rate15 Gal/minPilot LocationInternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-35 °F
Actuation TypePressure SensingMaximum Pressure Setting210 bar
Adjustment MechanismKnobMaximum Tank Pressure350 bar
Seal MaterialD-Ring (Standard)Weight1 lb
FunctionPilot Operated SequenceCavity SizeC10-3
Drain OptionExternalMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating5500 psiFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Operating Temperature-35 to +200 °FMaximum Operating Temperature+93 °C
Installation Torque51-55 lb-ftMaximum Operating Pressure380 bar
Maximum Flow Rate56.3 L/minStandard Setting Pressure1500 psi
Pressure Control Range200-3000 psiLeak Rate82 @ 3000 PSI (210 BAR) cm3/min
Reseat Pressure90% of set pressureCracking PressureN/A bar
Maximum Drain Flow Rate0.94 Gal/minPressure Control Sensitivity59 per turn bar
Seal MaterialD-Ring (Standard)Pilot OptionInternal
Drain OptionExternalAdjustment TypeKnob
Cracking Pressure (psi)N/APressure Range Adjustment (psi)200-3000
Rated Flow (gpm)15
Product resources