Parker SVH081T10 - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH081T10
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Minimum Operating Temperature-35Port Sizen/a
Body Materialn/aDivisionHydraulic Valve Systems Division
DivisionHydraulic Systems DivisionPilot LocationInternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Weight0.25
Maximum Operating Pressure5500Actuation TypePressure Sensing
Adjustment MechanismTamper ResistantMaximum Tank Pressure5000
Cracking Pressuren/aSeal MaterialD-Ring (Standard)
FunctionPilot Operated SequenceCavity SizeC08-3
Drain OptionExternalFlow Rate12
Maximum Flow Rate12Mounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating5500Maximum Operating Temperature+200
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Operating Temperature-35 to +200
Installation Torque32-36Maximum Pressure Setting1000
Standard Setting Pressure500Pressure Control Range100-1000
Maximum Drain Flow Rate0.15Pressure Control Sensitivity285 per turn
Leak Rate82 @ 3000 PSI (210 BAR)Reseat Pressure90% of set pressure
Seal MaterialD-Ring (Standard)Pilot OptionInternal
Drain OptionExternalRated Flow (gpm)12
Cracking Pressure (psi)N/APressure Range Adjustment (psi)100-1000
Adjustment TypeTamper Resistant
Product resources