Parker SVH081S10N - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH081S10N
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrilePort Sizen/a
Body Materialn/aDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionPilot LocationInternal
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-30 °F
Actuation TypePressure SensingAdjustment MechanismScrew
Maximum Tank Pressure350 barWeight0.25 lb
FunctionPilot Operated SequenceCavity SizeC08-3
Drain OptionExternalFlow Rate45 L/min
Maximum Flow Rate45 L/minMounting TypeThreaded Cartridge Valve
Maximum Inlet Pressure Rating380 barInstallation Torque43-49 Nm
Maximum Operating Temperature+121 °CFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-34 to +121 °C
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Maximum Operating Pressure380 bar
Maximum Pressure Setting69 barStandard Setting Pressure34.5 bar
Pressure Control Range6.9-69 barMaximum Drain Flow Rate0.15 Gal/min
Pressure Control Sensitivity285 per turn psiLeak Rate82 @ 3000 PSI (210 BAR) cm3/min
Reseat Pressure90% of set pressureCracking PressureN/A bar
Seal MaterialNitrilePilot OptionInternal
Drain OptionExternalAdjustment TypeScrew
Rated Flow (gpm)12Cracking Pressure (psi)N/A
Pressure Range Adjustment (psi)100-1000
Product resources