Parker SVH081K50 - Pilot Operated Sequence Valves

Parker’s pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. SVH081K50
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Port Sizen/aBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Pilot LocationInternalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-35 °FMaximum Operating Temperature+200 °F
Flow Rate12 Gal/minActuation TypePressure Sensing
Weight0.11 kgAdjustment MechanismKnob
Maximum Tank Pressure5000 psiSeal MaterialD-Ring (Standard)
FunctionPilot Operated SequenceCavity SizeC08-3
Drain OptionExternalMaximum Flow Rate12 Gal/min
Mounting TypeThreaded Cartridge ValveMaximum Inlet Pressure Rating380 bar
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Operating Temperature-37 to +93 °C
Installation Torque32-36 lb-ftMaximum Operating Pressure380 bar
Maximum Pressure Setting350 barStandard Setting Pressure172.4 bar
Pressure Control Sensitivity1910 per turn psiPressure Control Range200-5000 psi
Maximum Drain Flow Rate0.15 Gal/minLeak Rate82 @ 3000 PSI (210 BAR) cm3/min
Reseat Pressure90% of set pressureCracking PressureN/A bar
Seal MaterialD-Ring (Standard)Pilot OptionInternal
Drain OptionExternalAdjustment TypeKnob
Rated Flow (gpm)12Cracking Pressure (psi)N/A
Pressure Range Adjustment (psi)200-5000