Parker PRH161F30 - Pilot Operated Pressure Reducing Relieving Valves

Parker’s pilot operated acting reducing & relieving valves are used in applications where specific functions require reduced and regulated pressure. Capable of flows up to 150 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH161F30
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-30 °F
Weight0.34 kgMaximum Operating Pressure350 bar
Maximum Flow Rate40 Gal/minActuation TypePressure Sensing
Maximum Pressure Setting210 barOperation TypeAutomatic
FunctionPilot OperatedMaximum Tank Pressure350 bar
Port Thread Sizen/aCavity SizeC16-3
ConfigurationPressure Reducing/RelievingAdjustment MechanismFixed
Maximum Inlet Pressure Rating5500 psiMaximum Operating Temperature+250 °F
For Fluid TypeMineral-based or synthetic hydraulic fluidsValve MaterialAll parts steel. All operating parts hardened steel
Operating Temperature-34 to +121 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Mounting TypeScrew in cartridge valvePressure Control SensitivityN/A psi
Standard Setting Pressure1500 psiCracking PressureN/A psi
Flow Rate151.4 L/minInstallation Torque164-170 Nm
Pressure Control Range20.7-210 barMaximum Drain Flow Rate1.9 L/min
Leak Rate5 per 100 PSI (6.9 BAR) setting cc/minSeal MaterialNitrile
Mounting TypeScrew in cartridge valveCracking PressureN/A
Adjustment MechanismFixedFlow Rate40 GAL/MIN, 151.4 L/MIN
Pressure Control Range300-3000 PSI, 20.7-210 BAR