Parker PRH122K10 - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH122K10
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-30 °F
Maximum Operating Pressure350 barActuation TypePressure Sensing
Operation TypeAutomaticAdjustment MechanismKnob
FunctionPilot OperatedMaximum Tank Pressure5000 psi
Weight0.27 kgCavity SizeC12-3
Maximum Inlet Pressure Rating380 barInstallation Torque76 Nm
Maximum Operating Temperature+250 °FFor Fluid TypeMineral-based or synthetic hydraulic fluids
Operating Temperature-34 to +121 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Mounting TypeScrew in cartridge valveFlow Rate30 Gal/min
Valve MaterialAll parts steel. All operating parts hardened steel.Maximum Pressure Setting69 bar
Standard Setting Pressure500 psiConfigurationPressure Reducing
Pressure Control Range100-1000 psiMaximum Flow Rate113.7 L/min
Maximum Drain Flow Rate0.5 Gal/minPressure Control Sensitivity334 per turn psi
Seal MaterialNitrileAdjustment MechanismKnob
Pressure Control Range100-1000 PSI, 6.9-69 BARFlow Rate30 GAL/MIN, 113.7 L/MIN
Product resources