Parker PRH121K10V - Pilot Operated Pressure Reducing Relieving Valves

Parker’s pilot operated acting reducing & relieving valves are used in applications where specific functions require reduced and regulated pressure. Capable of flows up to 150 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH121K10V
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialFluorocarbonBody Materialn/a
Maximum Operating Pressure5000 psiDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-26 °CActuation TypePressure Sensing
Operation TypeAutomaticAdjustment MechanismKnob
FunctionPilot OperatedMaximum Tank Pressure350 bar
Port Thread Sizen/aWeight0.27 kg
Cavity SizeC12-3Maximum Flow Rate30 Gal/min
ConfigurationPressure Reducing/RelievingMaximum Inlet Pressure Rating5500 psi
Maximum Operating Temperature+204 °CFor Fluid TypeMineral-based or synthetic hydraulic fluids
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-26 to +204 °C
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Mounting TypeScrew in cartridge valve
Installation Torque75 NmLeak RateN/A cc/min
Maximum Drain Flow Rate0.25 Gal/minMaximum Pressure Setting1000 psi
Standard Setting Pressure34.5 barCracking PressureN/A psi
Pressure Control Range100-1000 psiFlow Rate113.7 L/min
Pressure Control Sensitivity23 per turn barSeal MaterialFluorocarbon
Adjustment MechanismKnobMounting TypeScrew in cartridge valve
Cracking PressureN/APressure Control Range100-1000 PSI, 6.9-69 BAR
Flow Rate30 GAL/MIN, 113.7 L/MIN
Product resources