Parker PRH082T50 - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH082T50
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Body Materialn/aDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-37 °CMaximum Operating Pressure350 bar
Maximum Flow Rate8 Gal/minActuation TypePressure Sensing
Operation TypeAutomaticAdjustment MechanismTamper Resistant
FunctionPilot OperatedFlow Rate8 Gal/min
Maximum Tank Pressure5000 psiSeal MaterialD-Ring (Standard)
Weight0.25 lbCavity SizeC08-3
Maximum Inlet Pressure Rating5500 psiFor Fluid TypeMineral-based or synthetic hydraulic fluids
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Mounting TypeScrew in cartridge valve
Operating Temperature-37 to +93 °CMaximum Operating Temperature+93 °C
Installation Torque32-36 lb-ftValve MaterialAll parts steel. All operating parts hardened steel.
Maximum Pressure Setting350 barStandard Setting Pressure2500 psi
ConfigurationPressure ReducingPressure Control Range200-5000 psi
Maximum Drain Flow Rate0.15 Gal/minPressure Control Sensitivity1996 per turn psi
Adjustment MechanismTamper ResistantFlow Rate8 GAL/MIN, 30 L/MIN
Seal MaterialD-Ring (Standard)Pressure Control Range200-5000 PSI, 13.8-350 BAR
Product resources