Parker PRH082S50V - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH082S50V
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialFluorocarbonBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-15 °F
Maximum Operating Pressure350 barMaximum Flow Rate30 L/min
Actuation TypePressure SensingOperation TypeAutomatic
Adjustment MechanismScrewFunctionPilot Operated
Flow Rate8 Gal/minMaximum Tank Pressure5000 psi
Weight0.25 lbCavity SizeC08-3
Maximum Inlet Pressure Rating5500 psiInstallation Torque43-49 Nm
Maximum Operating Temperature+204 °CFor Fluid TypeMineral-based or synthetic hydraulic fluids
Operating Temperature-26 to +204 °CFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Mounting TypeScrew in cartridge valveValve MaterialAll parts steel. All operating parts hardened steel.
Maximum Pressure Setting350 barStandard Setting Pressure2500 psi
ConfigurationPressure ReducingPressure Control Range200-5000 psi
Maximum Drain Flow Rate0.15 Gal/minPressure Control Sensitivity1996 per turn psi
Seal MaterialFluorocarbonAdjustment MechanismScrew
Flow Rate8 GAL/MIN, 30 L/MINPressure Control Range200-5000 PSI, 13.8-350 BAR
Product resources