Parker PRH082S30V - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH082S30V
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialFluorocarbonBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-15 °F
Maximum Operating Pressure350 barMaximum Flow Rate30 L/min
Flow Rate30 L/minActuation TypePressure Sensing
Maximum Pressure Setting210 barWeight0.11 kg
Operation TypeAutomaticAdjustment MechanismScrew
FunctionPilot OperatedMaximum Tank Pressure350 bar
Cavity SizeC08-3Maximum Inlet Pressure Rating5500 psi
Maximum Operating Temperature+400 °FFor Fluid TypeMineral-based or synthetic hydraulic fluids
Operating Temperature-15 to +400 °FFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Mounting TypeScrew in cartridge valveInstallation Torque32-36 lb-ft
Valve MaterialAll parts steel. All operating parts hardened steel.Standard Setting Pressure103.5 bar
ConfigurationPressure ReducingPressure Control Range13.8-210 bar
Maximum Drain Flow Rate0.56 L/minPressure Control Sensitivity942 per turn psi
Seal MaterialFluorocarbonAdjustment MechanismScrew
Flow Rate8 GAL/MIN, 30 L/MINPressure Control Range200-3000 PSI, 13.8-210 BAR
Product resources