Parker PRH082K50 - Pilot Operated Pressure Reducing Valves

Parker’s pilot operated pressure reducing valves are capable of flows up to 150 lpm (40 gpm) and regulating pressures up to 350 bar (5000 psi) and are commonly used for setting the pressure of a sub-circuit within a hydraulic system.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PRH082K50
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Body Materialn/aDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-35 °FMaximum Operating Pressure350 bar
Flow Rate30 L/minMaximum Flow Rate8 Gal/min
Actuation TypePressure SensingWeight0.11 kg
Operation TypeAutomaticAdjustment MechanismKnob
FunctionPilot OperatedMaximum Tank Pressure350 bar
Seal MaterialD-Ring (Standard)Cavity SizeC08-3
Maximum Inlet Pressure Rating5500 psiInstallation Torque43-49 Nm
For Fluid TypeMineral-based or synthetic hydraulic fluidsFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Mounting TypeScrew in cartridge valveOperating Temperature-35 to +200 °F
Maximum Operating Temperature+93 °CValve MaterialAll parts steel. All operating parts hardened steel.
Maximum Pressure Setting350 barStandard Setting Pressure172.4 bar
ConfigurationPressure ReducingPressure Control Range13.8-350 bar
Maximum Drain Flow Rate0.56 L/minPressure Control Sensitivity137.6 per turn bar
Adjustment MechanismKnobFlow Rate8 GAL/MIN, 30 L/MIN
Seal MaterialD-Ring (Standard)Pressure Control Range200-5000 PSI, 13.8-350 BAR
Product resources