Products specifications
Attribute nameAttribute value
Seal MaterialNitrileConnection Sizen/a
Connection Typen/aBody Materialn/a
DivisionHydraulic Cartridge Systems DivisionDivisionHydraulic Systems Division
Flow DirectionBi-directionalMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Maximum Operating Pressure210 barMinimum Operating Temperature-34 °C
Weight0.12 kgFlow Rate30 L/min
Cavity SizeC10-2Coil Type5/8" Super Coil High Watt (CAP)
Power Consumption28 WInstallation Torque22 lb-ft
Coil Nut Tightening Torque4.1 NmMaximum Inlet Pressure Rating210 bar
Maximum Operating Temperature+121 °CFunctionProportional Flow Control/Regulator
Frequency100-400 HzActuation TypeElectrical, Manual
For Fluid TypeMineral-based or synthetic hydraulic fluidsOperation TypeSolenoid operated, Manually operated
Valve MaterialAll parts steel. All operating parts hardened steelOperating Temperature-30 to +250 °F
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Wire Mesh Screen IncludedNo
Variation of Opening PointN/AMinimum Pressure DifferentialN/A psi
Override FunctionalityInfinite ControlHysteresis< 10%
ConfigurationNormally Open, Partially Pressure CompensatedCurrentMax: 2.33 @ 12 VDC, 1.17 @ 24 VDC A
Leak Rate757 @ 3000 PSI (210 BAR) cm3/minMaximum Flow Rate30.0 L/min
Flow Rate Accuracy+/- 2%Variation of Closing Point65% of Input Signal
Seal MaterialNitrileActuation TypeElectrical, Manual
ConfigurationNormally Open, Partially Pressure CompensatedFlow Rate9.5 GAL/MIN, 36 L/MIN