Parker FP101F100 - Pressure Compensated Priority Flow Control Valves

Pressure compensated priority flow control valves maintain constant flow regardless of changes to inlet pressure for flows up to 90 lpm (24 gpm) and pressures up to 420 bar (6000 psi); excess flow is diverted once the priority flow requirement is met.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. FP101F100
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Maximum Operating Temperature+121 °CSeal MaterialNitrile
Flow Rate15 Gal/minDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Priority Flow8 Gal/min
Body Materialn/aStandard Flow Rate Setting3.8 L/min
Connection Typen/aMaximum Flow Rate15 Gal/min
Operation TypeAutomaticMaximum Inlet Pressure Rating245 bar
Minimum Operating Temperature-34 °CFor Fluid TypeMineral-based or synthetic hydraulic fluids
Weight0.23 kgFlow Rate Display RangeN/A L/min
Cavity SizeC10-3Operating Temperature-30 to +250 °F
ConfigurationPriority FlowConnection Sizen/a
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)FunctionFlow Regulator Valve
Flow Rate Accuracy20%Installation Torque16 lb-ft
Maximum Operating Pressure3500 psiValve MaterialAll parts steel. All operating parts hardened steel
Adjustment MechanismFixedActuation TypePressure Compensated
Maximum Regulated Flow RateN/A L/minFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Standard Flow Rate Setting1 GAL/MIN, 3.8 L/MINFlow Rate Display RangeN/A
Seal MaterialNitrileAdjustment MechanismFixed
Maximum Flow Rate15 GAL/MIN, 56.3 L/MIN