Parker B04J4GZNS - Direct Acting Sequence Valve

Parker’s direct acting sequence valves can be piloted and vented allowing multiple actuators to work in sequence based on pressure settings; working with flows up to 56 lpm (15 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. B04J4GZNS
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileMaximum Operating Temperature250 °F
Body Materialn/aMaximum Operating Pressure6000 psi
ConfigurationNormally Closed (NC)For Fluid TypeMineral-based Hydraulic Fluids
Pilot LocationExternalValve MaterialSteel (all parts)
Filter Efficiency RatingISO 4406 18/16/13Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-34 °CMounting TypeScrew-in Cartridge
Actuation TypePressure SensingDivisionMobile Hydraulic Systems Division Europe
Operation TypeAutomaticAdjustment MechanismScrew
Maximum Tank Pressure6000 psiOperating Temperature-34 to 121 °C
Maximum Inlet Pressure Rating6000 psiLeak Rate25 cm3/min @ 1450 Psi (100 bar)
Installation Torque50 NmFunctionDirect Acting Sequence
Drain OptionExternalSealed Pilot IncludedYes
Maximum Pressure Setting166 barStandard Setting Pressure1160 psi
Pressure Control Sensitivity248 psi Per TurnWeight0.73 lb
Flow Rate47 L/minCavity SizeC10-4
Maximum Flow Rate47 L/minPressure Control Range2 to 166 bar
Seal MaterialNitrileAdjustment MechanismScrew
Maximum Inlet Pressure Rating6000 PSI, 420 BARSealed Pilot IncludedYes
Pressure Control Range30-2400 PSI, 2-166 BARFlow Rate12 GAL/MIN, 47 L/MIN
Product resources