Parker B04H4EWN - Direct Acting Sequence Valve

Parker’s direct acting sequence valves can be piloted and vented allowing multiple actuators to work in sequence based on pressure settings; working with flows up to 56 lpm (15 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. B04H4EWN
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileMaximum Operating Temperature250 °F
Weight0.33 kgBody Materialn/a
ConfigurationNormally Closed (NC)For Fluid TypeMineral-based Hydraulic Fluids
Pilot LocationExternalFilter Efficiency RatingISO 4406 18/16/13
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-34 °C
Maximum Operating Pressure420 barMounting TypeScrew-in Cartridge
Actuation TypePressure SensingDivisionMobile Hydraulic Systems Division Europe
Operation TypeAutomaticValve MaterialHardened Steel (all operating parts)
Adjustment MechanismKnobMaximum Tank Pressure420 bar
Operating Temperature-34 to 121 °CMaximum Inlet Pressure Rating6000 psi
Leak Rate25 cm3/min @ 1450 Psi (100 bar)Installation Torque37 lb-ft
FunctionDirect Acting SequenceDrain OptionExternal
Sealed Pilot IncludedNoPressure Control Range2 to 80 bar
Maximum Pressure Setting1160 psiStandard Setting Pressure40 bar
Pressure Control Sensitivity8.7 bar Per TurnFlow Rate47 L/min
Cavity SizeC10-4Maximum Flow Rate12 Gal/min
Seal MaterialNitrileAdjustment MechanismKnob
Maximum Inlet Pressure Rating6000 PSI, 420 BARSealed Pilot IncludedNo
Pressure Control Range30-1160 PSI, 2-80 BARFlow Rate12 GAL/MIN, 47 L/MIN