Parker B04H4ETV - Direct Acting Sequence Valve

Parker’s direct acting sequence valves can be piloted and vented allowing multiple actuators to work in sequence based on pressure settings; working with flows up to 56 lpm (15 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. B04H4ETV
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Maximum Operating Temperature400 °FSeal MaterialFluorocarbon
Body Materialn/aMaximum Operating Pressure6000 psi
ConfigurationNormally Closed (NC)For Fluid TypeSynthetic Hydraulic Fluids
Pilot LocationExternalValve MaterialSteel (all parts)
Operating Temperature-15 to 400 °FFilter Efficiency RatingSAE Class 4
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-26 °C
Mounting TypeScrew-in CartridgeActuation TypePressure Sensing
DivisionMobile Hydraulic Systems Division EuropeOperation TypeAutomatic
Adjustment MechanismTamper ResistantMaximum Tank Pressure6000 psi
Maximum Inlet Pressure Rating420 barLeak Rate25 cm3/min @ 1450 Psi (100 bar)
Installation Torque37 lb-ftFunctionDirect Acting Sequence
Drain OptionExternalSealed Pilot IncludedNo
Pressure Control Range2 to 80 barMaximum Pressure Setting1160 psi
Standard Setting Pressure40 barPressure Control Sensitivity125 psi Per Turn
Weight0.73 lbFlow Rate47 L/min
Cavity SizeC10-4Maximum Flow Rate47 L/min
Seal MaterialFluorocarbonAdjustment MechanismTamper Resistant
Maximum Inlet Pressure Rating6000 PSI, 420 BARSealed Pilot IncludedNo
Pressure Control Range30-1160 PSI, 2-80 BARFlow Rate12 GAL/MIN, 47 L/MIN
Product resources