Parker B04G3GZNS - Direct Acting Sequence Valve

Parker’s direct acting sequence valves can be piloted and vented allowing multiple actuators to work in sequence based on pressure settings; working with flows up to 56 lpm (15 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. B04G3GZNS
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileMaximum Operating Temperature250 °F
Body Materialn/aMaximum Operating Pressure6000 psi
ConfigurationNormally Open (NO)For Fluid TypeSynthetic Hydraulic Fluids
Pilot LocationExternalFilter Efficiency RatingSAE Class 4
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Minimum Operating Temperature-30 °F
Mounting TypeScrew-in CartridgeActuation TypePressure Sensing
DivisionMobile Hydraulic Systems Division EuropeOperation TypeAutomatic
Valve MaterialHardened Steel (all operating parts)Adjustment MechanismScrew
Maximum Tank Pressure6000 psiOperating Temperature-34 to 121 °C
Maximum Inlet Pressure Rating6000 psiLeak Rate25 cm3/min @ 1450 Psi (100 bar)
Installation Torque37 lb-ftFunctionDirect Acting Sequence
Cavity SizeC10-3Drain OptionInternal
Sealed Pilot IncludedYesMaximum Pressure Setting2400 psi
Standard Setting Pressure1160 psiPressure Control Sensitivity17 bar Per Turn
Weight0.3 kgFlow Rate10.6 Gal/min
Maximum Flow Rate10.6 Gal/minPressure Control Range2 to 166 bar
Seal MaterialNitrileAdjustment MechanismScrew
Maximum Inlet Pressure Rating6000 PSI, 420 BARSealed Pilot IncludedYes
Pressure Control Range30-2400 PSI, 2-166 BARFlow Rate10.6 GAL/MIN, 40 L/MIN