Parker B04D3HWN - Pilot Operated Sequence Valve with Reverse Check

REGIONAL - Parker's pilot operated sequence valve with reverse check combines two functions into a single cartridge reducing space, components, and manifold complexity. Capable of flows up to 70 lpm (32 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. B04D3HWN
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileBody Materialn/a
Maximum Operating Pressure6000 psiDivisionHydraulic Cartridge Systems Division
Cavity SizeC10-3SFor Fluid TypeMineral-based Hydraulic Fluids
Pilot LocationInternalValve MaterialSteel (all parts)
Filter Efficiency RatingISO 4406 18/16/13Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-30 °FMaximum Operating Temperature121 °C
Weight0.25 kgMounting TypeScrew-in Cartridge
Actuation TypePressure SensingMaximum Pressure Setting3000 psi
DivisionMobile Hydraulic Systems Division EuropeOperation TypeAutomatic
Adjustment MechanismKnobMaximum Tank Pressure6000 psi
Operating Temperature-30 to 250 °FPressure Control Range10 to 210 bar
Pressure Control Sensitivity435 psi Per TurnMaximum Inlet Pressure Rating420 bar
Installation Torque50 NmStandard Setting Pressure1450 psi
Maximum Flow Rate18.5 Gal/minFunctionPilot Operated Sequence
Flow Rate18.5 Gal/minLeak Rate50 drops/min @ 1450 Psi (100 bar)
Drain OptionExternalConfigurationReverse Flow Check
Seal MaterialNitrileAdjustment MechanismKnob
Pressure Control Range145-3000 PSI, 10-210 BARFlow Rate18.5 GAL/MIN, 70 L/MIN
Product resources