Parker A02A2HZN - Direct Acting Relief Valves

Parker’s direct acting relief valves are available in several cavity sizes and are designed for continuous duty applications with pressures up to 420 bar (6000 psi) and flows up to 200 lpm (53 gpm).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. A02A2HZN
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Seal MaterialNitrileMaximum Operating Temperature250 °F
Body Materialn/aFor Fluid TypeSynthetic Hydraulic Fluids
Filter Efficiency RatingSAE Class 4Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-30 °FMaximum Operating Pressure420 bar
FunctionDirect ActingFlow Rate6 L/min
ConfigurationPressure ReliefMounting TypeScrew-in Cartridge
Actuation TypePressure SensingMaximum Flow Rate6 L/min
Maximum Pressure Setting3000 psiWeight0.11 kg
DivisionMobile Hydraulic Systems Division EuropeLeak Rate0.33 cm3/min @ 1450 Psi (100 bar)
Cavity SizeC08-2Operation TypeAutomatic
Valve MaterialHardened Steel (all operating parts)Reseat Pressuren/a
Installation Torque30 lb-ftAdjustment MechanismScrew
Maximum Tank Pressure6000 psiOperating Temperature-30 to 250 °F
Pressure Control Range10 to 210 barStandard Setting Pressure100 bar
Wire Mesh Screen Includedn/aPressure Control Sensitivity30 bar Per Turn
Maximum Inlet Pressure Rating6000 psiSeal MaterialNitrile
Flow Rate1.6 GAL/MIN, 6 L/MINAdjustment MechanismScrew
Pressure Control Range145-3000 PSI, 10-210 BARMaximum Inlet Pressure Rating6000 PSI, 420 BAR