Parker 910-000200-007 - 55 Series 10555

Low Flow, 2-way normally closed (NC) proportional valve with integrated thermal compensation to maintain accurate and repeatable flow over a wide range of media.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. 910-000200-007
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
FunctionNormally Closed (NC)Seal MaterialFKM
For Fluid TypeGasesMaximum Operating Pressure150 psi
Configurationn/aMaximum Operating Temperature55 °C
Input Voltage24 VDCActuation TypeSolenoid
DivisionPrecision Fluidics DivisionMounting TypeManifold
Operation TypeElectronicControl MethodCurrent or Voltage
Power Consumption1.0 WMax Order Quantity9
Standard Lead Time20Out of Stock Lead Time40
Minimum Operating Temperature41 °FShipping Weight0.35
Leak Rate< 0.016 cm3/min of Helium @ 150 PsiIndustry ApplicationInsufflators
Orifice Size0.116 inchLength1.79 inch
Weight63 gBody MaterialBrass 360 H02
Width0.63 inchHeight17 mm
Connection Size4-40 x 5/8" Pan Head Phillips ScrewCycles per Lifetime100 Million
Electrical Connection18" Wire LeadsVacuum to Pressure Range686.0 mm-Hg to Pressure Rating
Flow Rateup to 500 cm3/minConnection TypeMounting Screw
Maximum Flow Rate500 cm3/minThermal CompensationNon-Thermally Compensated
Maximum Operating Voltage24 VDC