Thermally compensated 2-way normally closed (NC) proportional valve designed to maintain accurate and repeatable flow over a wide range of media. Ideal for medical and analytical applications that require precision control and flow up to 56 slpm.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. 910-000048-005
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
FunctionNormally Closed (NC)Seal MaterialFKM
For Fluid TypeGasesMaximum Operating Pressure150 psi
Configurationn/aMaximum Operating Temperature55 °C
Power Consumption2.0 WActuation TypeSolenoid
DivisionPrecision Fluidics DivisionOperation TypeElectronic
Control MethodCurrent or VoltageMax Order Quantity9
Standard Lead Time20Out of Stock Lead Time40
Minimum Operating Temperature41 °FShipping Weight0.35
Leak Rate< 0.016 cm3/min of Helium @ 150 PsiMounting TypeMounting Screw
Connection TypeThreaded PortLength1.79 inch
Weight63 gFlow Rateup to 5.5 SLPM
Maximum Flow Rate5.5 SLPMWidth0.63 inch
Height17 mmOrifice Size0.010 inch
Input Voltage8 VDCCycles per Lifetime100 Million
Industry ApplicationAnesthesia Delivery & MonitorsThermal CompensationThermally Compensated
Electrical Connection4-Pin PCBVacuum to Pressure Range0-27 Inch-Hg
Body MaterialNickel-Plated Brass (Series 25 body)Connection Size10-32 Female Threaded Ports
Electrical ConnectionPC Board MountBody/Elastomer MaterialsBrass/FKM
Maximum Operating Voltage8 VDCMaximum Operating Pressure/Orifice Size150 psid/.010"
Body Style10-32 Female ThreadsPneumatic Connection10-32 Female Thread Body