Parker 910-000042-116 - 55 Series 10655

Thermally compensated 2-way normally closed (NC) proportional valve designed to maintain accurate and repeatable flow over a wide range of media. Ideal for medical and analytical applications that require precision control and flow up to 56 slpm.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. 910-000042-116
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
FunctionNormally Closed (NC)For Fluid TypeGases
Maximum Operating Pressure150 psiConfigurationn/a
Maximum Operating Temperature55 °CPower Consumption2.0 W
Actuation TypeSolenoidDivisionPrecision Fluidics Division
Operation TypeElectronicControl MethodCurrent or Voltage
Max Order Quantity9Standard Lead Time20
Out of Stock Lead Time40Shipping Weight0.35
Leak Rate< 0.016 cm3/min of Helium @ 150 PsiMounting TypeMounting Screw
Industry ApplicationPressure & Flow ControlInput Voltage20 VDC
Seal MaterialFFKMLength1.79 inch
Weight63 gFlow Rateup to 5.5 SLPM
Body MaterialBrass 360 H02Maximum Flow Rate5.5 SLPM
Minimum Operating Temperature5 °CWidth0.63 inch
Height0.67 inchOrifice Size0.010 inch
Connection Size4-40 x 5/8" Pan Head Phillips ScrewConnection TypeManifold Face Mount with Screens
Cycles per Lifetime100 MillionThermal CompensationThermally Compensated
Electrical Connection4-Pin PCBVacuum to Pressure Range0-27 Inch-Hg
Body StyleManifold Mount w/ ScreensPneumatic ConnectionSquare Body(Manifold and Barb)
Electrical ConnectionQuick SpadeBody/Elastomer MaterialsBrass/FFKM
Maximum Operating Voltage20 VDCMaximum Operating Pressure/Orifice Size150 psid/.010"
Product resources