Parker 910-000042-100 - 55 Series 10655

Thermally compensated 2-way normally closed (NC) proportional valve designed to maintain accurate and repeatable flow over a wide range of media. Ideal for medical and analytical applications that require precision control and flow up to 56 slpm.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. 910-000042-100
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
FunctionNormally Closed (NC)For Fluid TypeGases
Configurationn/aMaximum Operating Temperature131 °F
Power Consumption2.0 WMaximum Operating Pressure10.34 bar
Actuation TypeSolenoidDivisionPrecision Fluidics Division
Operation TypeElectronicControl MethodCurrent or Voltage
Max Order Quantity9Standard Lead Time20
Out of Stock Lead Time40Shipping Weight0.35
Leak Rate< 0.016 cm3/min of Helium @ 150 PsiMounting TypeMounting Screw
Industry ApplicationPressure & Flow ControlSeal MaterialFFKM
Weight2.2 ozFlow Rateup to 5.5 SLPM
Body MaterialBrass 360 H02Maximum Flow Rate5.5 SLPM
Minimum Operating Temperature5 °CWidth15.9 mm
Height17 mmLength45.3 mm
Orifice Size0.25 mmInput Voltage13.5 VDC
Connection Size4-40 x 5/8" Pan Head Phillips ScrewConnection TypeManifold Face Mount
Cycles per Lifetime100 MillionThermal CompensationThermally Compensated
Electrical Connection18" Wire LeadsVacuum to Pressure Range0-686 mm-Hg
Body StyleManifold MountPneumatic ConnectionSquare Body(Manifold and Barb)
Electrical Connection18" Wire LeadsBody/Elastomer MaterialsBrass/FFKM
Maximum Operating Voltage13.5 VDCMaximum Operating Pressure/Orifice Size150 psid/.010"