Parker 910-000042-036 - 55 Series 10655

Thermally compensated 2-way normally closed (NC) proportional valve designed to maintain accurate and repeatable flow over a wide range of media. Ideal for medical and analytical applications that require precision control and flow up to 56 slpm.
Availability:
Partner Available:Quote Required
Brand Parker
Part No. 910-000042-036
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
FunctionNormally Closed (NC)Seal MaterialFKM
For Fluid TypeGasesConfigurationn/a
Maximum Operating Temperature55 °CPower Consumption2.0 W
Maximum Operating Pressure10.34 barActuation TypeSolenoid
DivisionPrecision Fluidics DivisionOperation TypeElectronic
Control MethodCurrent or VoltageMax Order Quantity9
Standard Lead Time20Out of Stock Lead Time40
Minimum Operating Temperature41 °FShipping Weight0.35
Leak Rate< 0.016 cm3/min of Helium @ 150 PsiMounting TypeMounting Screw
Industry ApplicationVentilatorsLength1.79 inch
Weight2.2 ozFlow Rateup to 5.5 SLPM
Body MaterialBrass 360 H02Maximum Flow Rate5.5 SLPM
Width0.63 inchHeight17 mm
Orifice Size0.010 inchInput Voltage13.5 VDC
Connection Size1/8 inch Barb for I.D. TubingConnection TypeBarb
Cycles per Lifetime100 MillionThermal CompensationThermally Compensated
Electrical ConnectionQuick SpadeVacuum to Pressure Range0-27 Inch-Hg
Body Style1/8" BarbsPneumatic ConnectionSquare Body(Manifold and Barb)
Electrical ConnectionQuick SpadeBody/Elastomer MaterialsBrass/FKM
Maximum Operating Voltage13.5 VDCMaximum Operating Pressure/Orifice Size150 psid/.010"