Attribute nameAttribute value
Port TypeNPTPort Size1/4 inch
DivisionFluid Control DivisionMaximum Fluid Temperature150 °F
Maximum Pressure Differential150.0 psiActuation TypeInternal Pilot
Specifications MetEMCMinimum Fluid Temperature-40 °F
Body MaterialStainless Steel 303Insulation ClassF (155°C)
Input Voltage12 VDCPower Consumption10 W
Ingress Protection RatingULMediaInert Gases
FunctionSingle SolenoidCoil Type1/2" NPT Conduit with 18" Leads
Valve Type4-Way (5/2)Seal MaterialNBR - Low Temp
Main Flow Coefficient1.2 CvMinimum Pressure Differential30 psi
InstallationIOM 7505Orifice Size1/4 inch
Override Functionalityn/aPreventive Maintenance Kit7K701
Maximum Ambient Temperature167 °FPort TypeNPT
Input Voltage12.0Actuation TypeInternally Piloted
Insulation ClassClass FMaximum Fluid Temperature150.0
Maximum Pressure Differential150.0Maximum Ambient Temperature167.0
Body Material303 Stainless SteelPort Size1/4
Power Consumption10.0Ingress Protection RatingUL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C
Coil Type1/2" NPT Conduit with 18" LeadsMediaAir, Inert Gas
Function2 Position, Single SolenoidValve Type4 Way (5/2)
InstallationIOM 7701Orifice Size1/4
Seal MaterialNBR - Low TempSpecifications MetUL, CSA Listed General Purpose Valve for Hazardous Locations; SIL 3; CE - Low Voltage, EMC
Main Flow Coefficient1.2Minimum Fluid Temperature-40.0
Preventive Maintenance Kit7K701Minimum Pressure Differential30.0