Parker 73417BN2PN00N0H111P3 - 7 Family - 4 Way (5/2) Extreme-Duty VAP Valves

Parker's VAP (Valve Actuation Process) control valves are used in the word's toughest applications where uptime and compliance are critical.
AFP Availability:
Partner Available:Quote Required
Brand Parker
Part No. 73417BN2PN00N0H111P3
$458.45/each
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
UOMEAPort TypeNPT
Specifications MetEMCMaximum Pressure Differential150.0 psi
Maximum Fluid Temperature150 °FOrifice Size1/4 inch
Preventive Maintenance Kit7K701Power Consumption10 W
Seal MaterialNBR - Low TempInstallationIOM 7505
Actuation TypeInternal PilotOverride Functionalityn/a
Insulation ClassF (155°C)DivisionFluid Control Division
Maximum Ambient Temperature167 °FCoil Type1/2" NPT Conduit with 18" Leads
FunctionSingle SolenoidMinimum Fluid Temperature-40 °F
Valve Type4-Way (5/2)Body MaterialBrass
Input Voltage120/60 VACMain Flow Coefficient1.2 Cv
Minimum Pressure Differential30 psiMediaInert Gases
Ingress Protection RatingCSA Class 2, Div. 1, Group E,F,G to T3CPort Size1/4 inch
Port TypeNPTBody MaterialBRASS
Input Voltage120/60, 110/50Actuation TypeInternally Piloted
Insulation ClassClass FMaximum Fluid Temperature150.0
Maximum Pressure Differential150.0Maximum Ambient Temperature167.0
Port Size1/4Power Consumption10.0
Ingress Protection RatingUL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3CCoil Type1/2" NPT Conduit with 18" Leads
MediaAir, Inert GasFunction2 Position, Single Solenoid
Valve Type4 Way (5/2)InstallationIOM 7701
Orifice Size1/4Seal MaterialNBR - Low Temp
Specifications MetUL, CSA Listed General Purpose Valve for Hazardous Locations; SIL 3; CE - Low Voltage, EMCMain Flow Coefficient1.2
Minimum Fluid Temperature-40.0Preventive Maintenance Kit7K701
Minimum Pressure Differential30.0