• Availability & Price
  • Search SKU
Filter by attributes
  • Coil Type
  • Flow Factor 1 (Cv)
  • Maximum Pressure Differential (psi)
  • Orifice 1 Size (inch)
  • Power (Watts)
  • Seal Material
  • Voltage (V)
More Filters...
Filter by manufacturer
Manufacturers

Parker 2-Way Normally Open, 1/4" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Open, 1/4" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Open 1/4" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort TypePort SizeBody MaterialDivisionMediaFunctionCoil TypeValve TypeInput VoltageSeal MaterialOrifice 2 SizeNumber of PortsFlow Coefficient 2Coil Specifications MetMinimum Fluid TemperatureMinimum Pressure DifferentialMaximum Fluid TemperatureMaximum Pressure DifferentialActuation TypeProduct SeriesPower ConsumptionOrifice 1 SizeFlow Coefficient 1Coil TypeVoltage (V)Seal MaterialMaximum Pressure Differential (psi)Power (Watts)Flow Factor 1 (Cv)Orifice 1 Size (inch)
73222BN2MN00N0D100C1
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way12.0NBRn/a2n/aClass F05185200 psi (DC)Manual7000 Series10 W (DC)7/160.76DIN Form A, Class F12 VDCNBR200 psi (DC)10 Watt (DC)0.767/16
73222BN2MN00N0D100C2
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way24.0NBRn/a2n/aClass F05185200 psi (DC)Manual7000 Series10 W (DC)7/160.76DIN Form A, Class F24 VDCNBR200 psi (DC)10 Watt (DC)0.767/16
73222BN2MN00N0D100P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way110/50-120/60NBRn/a2n/aClass F05185200 psi (AC)Manual7000 Series10 W (AC)7/160.76DIN Form A, Class F110/50-120/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0D100Q3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way220/50 to 240/60NBRn/a2n/aClass F05185200 psi (AC)Manual7000 Series10 W (AC)7/160.76DIN Form A, Class F220/50-240/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0D200C1
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class H2-Way12.0NBRn/a2n/aClass H05185200 psi (DC)Manual7000 Series10 W (DC)7/160.76DIN Form A, Class H12 VDCNBR200 psi (DC)10 Watt (DC)0.767/16
73222BN2MN00N0D200P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class H2-Way110/50-120/60NBRn/a2n/aClass H05185200 psi (AC)Manual7000 Series10 W (AC)7/160.76DIN Form A, Class H110/50-120/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0H111C1
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way12.0 VDCNBRn/a2n/aNEMA 70 °F5 psi185 °F200 psi (DC)Manual7000 Series10 W (DC)7/16 inch0.76 Cv1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 912 VDCNBR200 psi (DC)10 Watt (DC)0.767/16
73222BN2MN00N0H111C2
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionLiquids and GasesNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way24.0 VDCNBRn/a2n/aNEMA 70 °F5 psi185 °F200 psi (DC)Manual7000 Series10 W (DC)7/16 inch0.76 Cv1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 924 VDCNBR200 psi (DC)10 Watt (DC)0.767/16
73222BN2MN00N0H111P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way110/50-120/60NBRn/a2n/aNEMA 905185200 psi (AC)Manual7000 Series10 W (AC)7/160.761/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9110/50-120/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0H111Q3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way220/50 to 240/60NBRn/a2n/aNEMA 905185200 psi (AC)Manual7000 Series10 W (AC)7/160.761/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9220/50-240/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0H222C2
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 92-Way24.0NBRn/a2n/aNEMA 905185200 psi (DC)Manual7000 Series10 W (DC)7/160.761/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 924 VDCNBR200 psi (DC)10 Watt (DC)0.767/16
73222BN2MN00N0H222P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 92-Way110/50-120/60NBRn/a2n/aNEMA 905185200 psi (AC)Manual7000 Series10 W (AC)7/160.761/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9110/50-120/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0H222Q3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 92-Way220/50 to 240/60NBRn/a2n/aNEMA 905185200 psi (AC)Manual7000 Series10 W (AC)7/160.761/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9220/50-240/60NBR200 psi (AC)10 Watt (AC)0.767/16
73222BN2MN00N0T100P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/4 " Tab Terminal, Class F2-Way110/50-120/60NBRn/a2n/aClass F05185200 psi (AC)Manual7000 Series10 W (AC)7/160.761/4 " Tab Terminal, Class F110/50-120/60NBR200 psi (AC)10 Watt (AC)0.767/16